My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0013101
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1767
>
3500 - Local Oversight Program
>
PR0545247
>
ARCHIVED REPORTS_XR0013101
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 1:43:00 PM
Creation date
1/30/2020 11:13:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0013101
RECORD_ID
PR0545247
PE
3528
FACILITY_ID
FA0009790
FACILITY_NAME
CITY OF STOCKTON FIRE STATION #7
STREET_NUMBER
1767
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07509036
CURRENT_STATUS
02
SITE_LOCATION
1767 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
!.. Sold <br /> L <br /> City of Stockton A681OZOIB <br /> LJuly 18, 1997 Page A-4 <br /> Matrix spikes are analyzed in duplicate to validate the accuracy and precision <br /> Lof the method; and <br /> ■ During groundwater sampling,a travel blank sample consisting of organic-free <br /> t water is prepared and containerized in the laboratory, transported to the site, <br /> Land handled and transported in the same manner as the groundwater samples. <br /> A-5 Standard 09crating -P—weedglis for Using ftotolonization r n <br /> Draggl± Tubes: The PID is calibrated in accordance with the manufacture's <br /> recommendations prior to use in the field. Upon arrival at the project site, the PID is used <br /> to monitor background concentrations of organic vapors in the atmosphere at the site. The <br /> background concentrations are measured in a location upwind and removed as possible from <br /> sources of organic vapors on the site. When background concentrations of organic vapors <br /> register as "0.0" on the PID, subsequent readings of"0.0" registered from samples tested in <br /> L, the field are recorded as WD" (not detected). When background concentrations of organic <br /> vapors register at some quantity above "0.0", subsequent readings registered from samples i <br /> tested in the field at or below this value are recorded as "B/G" (background). <br /> The Dragers tubes used is dependent on the type of analyte which is suspected as being <br /> L present on the project site (i.e. for gasoline product use the benzene tube, for diesel product <br /> use the petrol-hydrocarbon tube, etc.). Prior to use the tubes are examined to insure the <br /> shelf life expiration date has not expired and the tube has not been opened or damaged. <br /> L Tubes are only used for one test. The Drager® Gas Detector Pump is used with Dragerm <br /> tubes to insure accuracy. Prior to use the pump is examined to insure it is in proper <br /> operating condition. <br /> LThe tube is opened and inserted into the pump just prior to use. The pump is stroked the <br /> number of times required by the specific tube in use (i.e. 2 strokes for the petrol- <br /> hydrocarbon tube). After each stroke the pump is allowed to open to the full extent of the <br /> arrestor chain (10 to 20 seconds). <br /> i <br /> LIf the analyte is present in the sample, the material within the tube will discolor. The extent <br /> of the discolored material corresponds to the concentration of the analyte present. Readings <br /> from the tube are recorded based upon the amount of discolored material read from the <br /> calibrated markings on the tube. In the event the discoloration should extend beyond one <br /> marking but not to the next, this is recorded as "greater than (>)" the lower value. (i.e. if <br /> the discoloration extends beyond 300 parts per million (ppm) but does not reach 500 ppm, <br /> Lthis would be recorded as >300 ppm). The exception to this is when the discoloration reads <br /> less than the lowest value, this is recorded as "less than (<)" the lowest value on the tube. <br /> LAfter use tubes are disposed of as hazardous material because the contents are corrosive. <br /> A-6 Standard OpgratingProgedures for Performing Hgad S12ace An : Head space <br /> analysis may be performed using a photoionization detector (PID) or a drager tube. A soil <br /> L <br />