RPr-cNEI) J J N 1 71898 <br /> ' S <br /> PUBLIC HEALTH SERVICES <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DIVISION <br /> Karen Furst, M.D., M.P.H., Health Officer ' <br /> 304 East Weber Avenue, Third Floor - Srockton, CA 95242 <br /> 209/468-3420 [P <br /> LARRY WRAY Is im <br /> INLAND FAINT COMPANY <br /> 117 W HAM ING WAY <br /> STOCKTON CA 95204 <br /> RE: Inland Paint Store SITE CODE: 1133 <br /> 117 W. Harding Way <br /> Stockton, CA., 95244 <br /> San Joaquin County Public Health Services, Environmental Health Division (PHS-EHD) <br /> has reviewed the "Work Plan for Sail Excavation and Additional Subsurface <br /> Investigation" dated_June 5, 1998 as submitted.by ATC Associates Inc., on June 8, 1998 <br /> and offers the following comments for your review. <br /> Based on a underground storage tank (UST) site investigation recently completed near- <br /> by, the groundwater gradient in this area has been to the north-east. By proposing only <br /> two monitoring well installations north of the former UST, this site may not have an "up- <br /> gradient" well required for UST investigations. The monitoring wells at 340 W. Harding <br /> have been destroyed. A third (shallow) monitoring well for your investigation is required. <br /> PHS-EHD will require the proposed 70 foot deep soil boring in the former UST pit to be <br /> converted into the third (shallow) monitoring well. In addition, if the soil appears <br /> impacted by hydrocarbons at 70' deep, PHS-EHD recommends an additional monitoring <br /> well with a "deep-screened" interval be installed. An addendum should be submitted to <br /> PHS-EHD with the construction details for this deep monitoring well installation. This <br /> deep well should be constructed with a 5 foot screened interval placed at the most <br /> permeable soil layer near any deep contaminated soil detected with field screening <br /> devices. Both casings may be constructed within the same boring (nested) or another <br /> boring should be drilled within the former UST pit_ <br /> Included in the work plan are pians to over-excavate soil from the former UST pit. This <br /> plan is a "corrective action" and as such, is required to adhere to UST Regulations for <br /> Public Participation prior to its enactment. Please submit an Executive Summary and <br /> two copies of the modified work plan. The Executive Summary should be a one page <br /> document written in non-technical language that describes the site's history, current site <br /> status, and the remediation pian. This document, as well as a Notice of Findings, will be <br /> posted for the general public to review and comment on. It will direct all questions or <br /> concerns to PHS-EHD staff, Michael Infuma, Senior REHS. <br /> A Division of San Joaquin Counry Health Care Servi= <br />