Laserfiche WebLink
Mr Paul Supple Project 20805-140 003 <br /> Apn130, 1998 <br /> Page 7 <br /> The soil sample collected from beneath the waste oil UST was below method reporting <br /> hnuts for TPHG, TPHD, BTEX, MTBE, HVOCs, and PCBs The sample contained <br /> concentrations of chronuum, nickel, and zinc at 9 6, 5 0, and 25 mg/kg, respectively <br /> Piping Excavation and Dispenser Soil Samples <br /> Low concentrations of TPHG and BTEX were detected in soil samples PL-3, PL-10, and <br /> PL-17 collected from the piping trenches Detected TPHG concentrations in soil samples <br /> collected beneath the first and second sets of piping at depths of 3 to 4 feet bgs ranged <br /> from 13 to 12 mg/kg, respectively The detected benzene concentrations ranged <br /> from 0 0054 to 0 03 mg/kg, and detected MTBE concentrations ranged from <br /> 0 26 to 0 51 mg/kg Petroleum hydrocarbons did not exceed method reporting limits in <br /> other piping excavation soil samples In addition, soli sample D-1 collected from the <br /> former dispenser location contained TPHG, benzene, and MTBE concentrations of <br /> 6 4, 0 0058, and 0 62 mg/kg, respectively Analytical results for samples D-2 through <br /> D-4 were below method reporting limits Oxygenates analyzed using USEPA <br /> Method 8260 did not exceed laboratory method reporting limits in piping excavation or <br /> dispenser soil samples See Table 1 for analytical results and the appendix for copies of <br /> certified analytical reports <br /> Soil Stockpiles <br /> Soil stockpile SP-1 contained approximately 250 cubic yards of soil generated from the <br /> gasoline UST excavation, and stockpile SP-2 contained approximately 11 cubic yards of <br /> soil generated during the removal of the waste oil UST In addition, stockpile SP-3 <br /> contained approximately 40 cubic yards of soil from the former dispenser and product <br /> piping trenches <br /> Analytical results of the five two-point composite samples collected from stockpile SP-1 <br /> contained concentrations of TPHG ranging from 2 2 to 19 mg/kg Benzene was below <br /> the method reporting limit, and MTBE, using USEPA Method 8020, ranged from below <br /> the method reporting lnrut to 0 94 mg/kg MTBE, using USEPA Method 8260, was <br /> detected in samples SP-1-2A/2B and SP-1-5A/5B at concentrations of 0 270 and <br /> 0 250 mg/kg, respectively Tertiary butanol was also detected in sample SP-1-5A/5B at a <br /> concentration of I1 mg/kg <br /> Stockpile SP-2A/2B contained concentrations of TPHD, TOG, and tetrachloroethene at <br /> 21, 610, and 0 096 mg/kg, respectively Chromium, nickel, and zinc were also detected <br /> in sample SP-2A/2B at concentrations of 17, 21, and 30 mg/kg, respectively <br /> SAON\PJft805\08051400 3FS-98\pzusmer 1 ;VCMK C& <br />