Laserfiche WebLink
- i <br /> 1 <br /> not sampled. Wells VW-1, VW-2, VW-3, VW-4, and VW-5D were not purged prior to sampling because <br /> . the screened intervals in these wells are not submerged, and the wells were not purged during previous <br /> sampling events. <br /> The groundwater flow direction was calculated to be towards the east-northeast at an average gradient of <br /> 0.0026 ft/ft. An eastward groundwater flow direction is consistent with previous quarters. The <br /> groundwater elevation has increased by more than 0.5 feet across the site since the previous sampling <br /> event(September 2001). <br /> A Delta technician conducted five site visits to optimize and maintain the SVE/AS system. Approximately <br /> 246 lbs of TPHG as gasoline was removed during the fourth quarter 2001, and a cumulative mass of <br /> 1,276.53 lbs since startup (09128100). The SVE system was shutdown between November 9, 2001, and <br /> November 26, 2001, due to a power outage. Upon system restart on November 26, 2001, soil vapor <br /> concentrations were low and therefore the system was shutdown to allow soil vapor concentrations to <br /> rebound. During the first quarter 2002, Delta will restart the system and optimize the operation of the SVE <br /> system. The SVE system is in compliance with San Joaquin Valley Unified Air Pollution Control District <br /> permit to operate. <br /> The air sparge system was shutdown between October 15, 2001, and October 22, 2001, due to <br /> mechanical problems. On October 22, 2001, a Delta technician re-started the AS system after installing a <br /> new belt and air cleaning filters on the air sparge compressor. Due to a power outage, the AS system <br /> shut down on November 19, 2001. The AS system was not restarted as the SVE system was shut down. <br /> The AS system will be restarted along with the SVE system. Delta is currently injecting ambient air in <br /> three sparge wells (AS-1 through AS-3) at flow rates in the range of 0.33 to 0.66 cubic feet per minute <br /> (cfm) at approximately 10.0 pounds per square inch (psi). <br /> • ATTACHMENTS: <br /> • Table 1 Groundwater Monitoring Data <br /> • Table 2 Groundwater Analytical Results for Oxygenates and Additional Compounds <br /> • Table 3 Floating Product Monitoring Summary, Well VW-5D <br /> • Table 4 Operational Uptime Information of the Soil Vapor Extraction System <br /> • Table 5 Flow Rates and Analytical Results of Air Sample Analyses <br /> • Table 6 Extraction and Emission Rates <br /> Figure 1 Site Location Map <br /> • Figure 2 Groundwater Elevation Contours, 4"'Quarter 2001 <br /> • Figure 3 Groundwater Analytical Summary 4`h Quarter 2001 <br /> • . Figure 4 Influent Concentrations vs Time <br /> • Figure 5 Cumulative Mass Removed vs Time <br /> • Appendix A Field Data Sheets <br /> • Appendix B Sampling and Analysis Procedures <br /> • Appendix C Certified Analytical Reports and Chain-of-Custody Records <br /> P:IARCO%05481QTRLWOOI1Arco_0548_4QO1.doc Delta <br />