Laserfiche WebLink
Site Safety Plan-October 14, 1992 Working To Restore Nature <br /> BP Oil.Facility No.11193; Stockton, CA <br /> HAZARD .ASSESSMENT <br /> The mor contaminants expected to be encountered on the project are gasoline and its hydrocarbon <br /> constituajents. The anticipated contaminants and their exposure standards are listed in Table.1. It is <br /> not anticipated that the potential levels.of exposure will reach the permissible exposure limits(PEL) <br /> orthreshold limit values (TLV). Inhalation I and dermal contact are the potential exposure <br /> pathways. Protective clothing will"be mandatory for field_personnel,specified in this Plan. In <br /> addition, respiratory ;protective devices-.are required to be worn;by each person onsite or to be <br /> within easy reach should irritating odors be detected or irritation of the respiratory tract occur. <br /> TABLE 1 <br /> EXPOSURE LIMITS OF ANTICIPATED CHEMICAL CONTAMINANTS <br /> 'BP Oil Facility No. 11193 <br /> Kelly-Drive.&Hammer Lane <br /> 'Stockton,California <br /> .(page 1 of 2) <br /> Contaminant PEL EL ED CL TWA STEL <br /> Benzenel •[.skirt] 1* 10* 5* <br /> .(c:arc) <br /> Ethylbenzene 100* <br /> 100* ' 125* <br /> Gasoline2 300* 300* 500* <br /> Toluene[skin] 100* 200* 10 min per 500* 100* 150* <br /> 8 hrs` <br /> ..Xylene -(a,m, 100* 200* 30 min per . 300* 100* 150* <br /> & p isomers) 8 hrs <br /> [skin] <br /> See-notes on page 2 of 2. <br /> 17051.O1SSP 3 <br /> L <br />