My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002603
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
3500 - Local Oversight Program
>
PR0545273
>
ARCHIVED REPORTS_XR0002603
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 6:51:44 PM
Creation date
2/3/2020 11:13:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002603
RECORD_ID
PR0545273
PE
3528
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
02
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 SUMMARY OF SITE ASSESSMENT ACTIVITIES AND <br /> SUBSURFACE CONDITIONS <br /> There are two former UST pits at this site The north former UST pit is located to the west of the <br /> current UST pit, and formerly contained one 10,000-gallon gasoline UST, and one 8,000-gallon <br /> and one 6,000-gallon diesel USTs The south former UST pit is located in the southeastern area <br /> of the site and formerly contained one 12,000-gallon diesel UST Petroleum hydrocarbon impact <br /> has been identified in the soil and groundwater beneath the Joe's Truck Plaza site The following <br /> sections summarize the environmental activities performed to date, and discuss the geologic and <br /> hydrologic conditions beneath the site and the lateral and vertical extent of petroleum <br /> hydrocarbon impact These discussions are based on our review of the following documents <br /> • Advanced GeoEnvironmental, Preliminary Site Assessment Report, Joe's Truck Stop, <br /> January 24, 1997 <br /> • Avalon Environmental Consultants, Phase II Environmental Assessment of Soil and <br /> Groundwater, Joe's Place Truck Stop, December 5, 1998 <br /> • Avalon Environmental Consultants, Phase II Groundwater Assessment Performed at <br /> Joe's Truck Plaza, March 20, 2000 <br /> • Avalon Environmental Consultants, Phase II Environmental Assessment of Soil and <br /> Groundwater, Joe's Place Truck Stop, April 15, 2001 <br /> • Avalon Environmental Consultants, Phase II Environmental Assessment of Soil and <br /> Groundwater, Joe's Place Truck Stop, May 15, 2002 <br /> • Avalon Environmental Consultants, Quarterly Groundwater Monitoring Reports, First <br /> Quarter 2000 (February 12, 2000) through Second Quarter 2003 (June 23, 2003) <br /> Approximate locations of current and former USTs, soil borings, and wells are included on <br /> Figures 2 and 3 A drilling and well construction summary of all soil bonngs and wells is <br /> included in Table 2 Boring logs are included in Appendix A Historical groundwater analytical <br /> data are included in Appendix B Historical soil analytical data are included in Appendix C <br /> 3.1 Environmental Investigations <br /> • In January 1997, a preliminary site assessment was performed by Advanced <br /> GeoEnvironmental, Inc (Advanced) The assessment activities consisted of advancing <br /> six soil borings in the vicinity of the northern and southern tank pits, and one boring in <br /> the vicinity of former septic leach lines (Figure 3), collecting soil samples, and collecting <br /> grab groundwater samples TPHD was reported in one of the soil samples collected from <br /> the depth of approximately 6 feet bgs near the southern tank pit at the concentration of <br /> 1,000 mg/Kg Dissolved TPHD, TPHG, and MTBE were reported in groundwater <br /> samples collected from borings near both tank pits at concentrations up to 320,000 µg/L, <br /> 2,700 µg/L, and 95 µg/L, respectively <br /> P\Joe's Truck P]aza\ReportslSCM_09-2003\Joes truck plaza SCM doc Page 5 0TRA TU5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.