Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.or0/ehd/ <br /> HAZARDOUS WASTE PROGRAM INSPECTION REPORT <br /> N8m" Diablo Auto Body nae""ress:7710 Murray Drive, Stockton rtsron 09/21/2010 <br /> if V R Coda Section HSC=CA Health&Safe Code;CCR=CA Code VIOLATIONS iatuo s;V=Violation RV=Repeat Violation V <br /> 44 CCR 66265.51 Failed to:(a)prepare a contingency plan;(b)implement contingency plan <br /> 45 CCR 66265.52 Contingency plan incomplete <br /> 46 CCR 66265.53(a) Contingency plan not on site <br /> €+ 47 CCR 66265.55 No emergency coordinator <br /> z <br /> °u 5 48 CCR B6265.56Q) Failed to submit written incident report to the Department within 15 days <br /> a 49 CCR 66265.16 Personnel training records Incomplete <br /> 50 X CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days <br /> E 51 CCR 66262.34(d)(1) Accumulated more than 6,000 kg of HW onsite at one time <br /> -O+ Failed to comply with Code of Federal Regulations 262.34(d),(e)&in <br /> Oy o CFR 262.34(dX5)(i)No emergency coordinator <br /> 52 X CCR 66262.34(d)(2) CFR 262.34(dX5)(ii)No modified contingency plan <br /> v CFR 262.34(d)(5)(iii)Failed to train all employees on waste handling and emergency procedures <br /> CFR 262. d 5 iv Failed to respond to a fire,spill or other release <br /> a 53 HSC 25244.4 Failed to submit a report to the Department at least every two years <br /> pp 54 HSC 25244.19 Failed to conduct source reduction/evaluation of site and prepare waste minimization plan <br /> N 55 HSC 25244.21 Failed to retain current(SB14)review and plan <br /> 56 HSC 25160(b)(3) Failed to submit TSDF manifest to the Department for Out-Of-State shipments <br /> LL 57 CCR 66262.20 Failed to prepare manifests for transportation of hazardous waste <br /> 58 CCR 66262.23(a) Failed to:(1)complete,sign or date manifest;(2)obtain dated signature of transporter <br /> 59 CCR 66262.23(a)(4) Failed to send generator manifest copies to the Department within 30 days <br /> mO 60 X CCR 66262.40(a) Failed to keep signed copy for 3 years <br /> qZ <br /> o 61 X CCR 66262.42(a) Failed to determine status of hazardous waste when manifest copy not received <br /> W5 62 X CCR 66262.42(b) Failed to file an exception report <br /> g: 63 HSC 25160.2(bX3) Failed to keep a copy of the consolidated manifest for 3 years <br /> f64 CCR 66266.81(aX4)(8) Failed to retain copy of manifest or bill of lading for spent lead acid batteries <br /> 65 HSC 25160.2(b)(4) Consolidated manifest receipts failed to contain complete information <br /> 661 1 1 HSC 25250.23 Transported used oil and not registered as a hazardous waste hauler <br /> m 67 CCR 66262.40(c) Failed to retain waste analysis on site for 3 years <br /> w 68 CCR 66262.41(a) Failed to submit Biennial Report to the Department <br /> W 691 1 1 CCR 66262.40(b) Failed to retain copy of Biennial RepoNException Report for 3 years <br /> w 701 1 1 CCR 66265.77(a) Failed to report releases to the Department <br /> 71 HSC 25160(d) Transported hazardous waste without a manifest <br /> 72 HSC 25163(a) Transported hazardous waste or transferred HW to a transporter without valid registration <br /> `g 73 HSC 25160.2(c)(2) Offered ineligible waste streams to be transported using consolidated manifest <br /> 74 CCR 66263.17(a) Transported HW without receiving ID Number and registration cert from DTSC <br /> 75 CCR 66263.23(b) Delivered hazardous waste to an unauthorized facility <br /> 76 CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID#prior to accumulating>5000kg of UW <br /> 77 CCR 66273.32(c) Cathode Ray Tube(CRT)handler failed to notify DTSC 30 days prior to accepting offsite UW <br /> 78 CCR 66273.33(a) Failed to store UW batteries in a closed container and in a manner that prevents breakage and release to <br /> the environment <br /> W Failed o:(1)stone UW lamps In a dosed container and in a manner that prevents breakage and release o the <br /> .33(b) <br /> W 79 CCR 66273envlronmem.or 2 immediately dean and containerize any broken lamps or releases to the environment <br /> 4 Failed to store mercury containing UW in dosed or airtight containers in a manner that prevents breakage <br /> 'T+ 80 CCR 66273.33(c) and release to the environment,or failed to immediately clean and containerize any broken mercury <br /> Qcontaining UW or release to the environment <br /> Failed to:(1)store a UVV electronic device in a manner at prevents breakage and release o environment,virom <br /> nent,or <br /> 81 CCR 66273.33.5(a)(1)(8) th <br /> 2 immediate) dean and containerize an broken electronic device or release to the environment <br /> ZW Failed to:(1)contain a CRT in a manner that prevents breakage and release to the environment,or(2) <br /> 82 CCR 66273.33.5(b)(1)(8) immediately dean and containerize any broken CRT or release to the environment <br /> Failed o laversa <br /> bel unil waste o identify <br /> 83 CCR 66273.34 fry type of universal waste. (a)Batteries,(b)Mercury containing <br /> equipment. c Lamps.A Electronic devices, a CRTs, CRT glass <br /> 84 CCR 66273.35 (a)Stored UW onsite for more than 1 year,or(b)was unable to demonstrate the length of time Ore UW has <br /> been accumulated from the date it became a waste or was received <br /> 85 CCR 66273.39 Failed to keep records of each shipment of universal waste according to this section <br /> 999 Other. See attached"Continuation-Oficial Inspection Report'for violation(s)not listed above. <br /> UIC Se t c System: a Serves s 20 persons/day r Recelves other than sanitary waste Dry wells/French Drab;Onsite <br /> 1m pwre! Received Title: <br /> 209 468-2986 1 By: <br /> EH 2- 84Page 2 HW INSPECTION REPORT <br />