• Steel-toed Boots <br /> • Orange Safety Vest (on roadways or construction areas) <br /> Modified Level D (One or more of the following) <br /> • Latex Gloves (when handling samples or sampling equipment) <br /> • Tyvek Coverall <br /> • Hearing protection (muffs and/or plugs). <br /> • Photo Ionization Detector (PID) (tasks requiring air monitoring) <br /> 4.4 Air Monitoring and Site Action Levels <br /> Air monitoring equipment shall include a photo ionization detector (PID) drilling/probing and <br /> sampling activities. PID monitoring will be conducted in the breathing zones to obtain accurate <br /> estimates of exposure. The PID measures total VOCs and does not usually respond to any <br /> particular substance where mixtures may be present. The PID instrument shall be calibrated and <br /> properly maintained per the manufactures guidelines. Personnel responsible for monitoring shall <br /> review the manufacturer's information prior to use of an instrument to familiarize themselves <br /> with proper operation and limitations. The project air monitoring action levels and equipment <br /> are summarized below. <br /> Air Monitoring Action Levels <br /> Instrument Frequency Action Levels Calibration/Gas <br /> At the beginning of Breathing Zone: Calibrate per <br /> Photo Ionization operations and <5 ppm Level D manufacturers <br /> Detector (PID) before sampling >5 ppm Stop work; Evacuate procedures <br /> & Vent <br /> Monitor every 15 Reevaluate level of protection if PID gas = 100 ppm <br /> minutes if reading levels continue to exceed 5 ppm in Methane <br /> elevated. the breathing zone <br /> HEALTH& SAFETYPLANn H November 2W <br /> TREADWELL & ROLLO,. INC, > zs97.11HASP-2 <br /> i <br />