copy6ghk @ 2003 <br /> E <br /> 1.0 INTRODUCTION <br /> THE ENCLOSED DRAWINGS AND SPECIFICATIONS CONTAIN INFORMATION FOR THE 3. PIPING TRENCHES AND EXCAVATIONS SHALL BE BACKFILLED WITH 2.5 ELECTRICAL(CONTINUED) <br /> CONSTRUCTION AND INSTALLATION OF A 810SPARGE REMEDIATION SYSTEM.THE IMPORTED SAND FROM 2 INCHES BELOW THE PIPING TO 2 INCHES ABOVE ENGINEER - ARCADIS <br /> FOLLOWING DRAWINGS DEPICTING THE REMEDIATION SYSTEM ARE REQUIRED FOR THE TOP OF PIPING, EXCAVATED SOIL SHALL BE USED AS BACKFILL <br /> 4. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE <br /> { CONSTRUCTION AND INSTALLATION: MATERIAL FROM 2 INCHES ABOVE TOP OF PIPING TO GROUND LEVEL. MOST RECENT EDITION OF THE NEC,THE LOCAL BUILDING DEPARTMENT, CONTRACTDR - TBD <br /> THE BACKFILL MATERIAL SHALL BE COMPACTED TO 95%OF THE RELATIVE AND THE LOCAL FIRE DEPARTMENT. ANY DRAWINGS REQUIRED FOR <br /> DRAWING NO. REVISION TITLEPERMITS OTHER THAN THOSE PRESENTED HEREIN WILL BE THE: <br /> G-1A,B 0 CONSTRUCTION NOTES AND SPECIFICATIONS SHEET DRY DENSITY IN LOOSE 8 INCH LEFTS. RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REVIEWED BY THE <br /> G-2 0 MAJOR EQUIPMENT AND INSTRUMENTATION LIST 4, THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENGINEER PRIOR TO USE, <br /> P-1 0 PROCESS AND INSTRUMENTATION DIAGRAM <br /> C-1 0 SITE PLAN AND PIPING LAYOUT PREVENT DAMAGE TO UNDERGROUND UTILITIES,PIPING,AND 5. THE INSTALLATION WITHIN THE EQUIPMENT ENCLOSURE SHALL COMPLY <br /> C-2 0 EQUIPMENT LAYOUT AND ELEVATIONS ADJOINING STRUCTURES, WITH THE APPROPRIATE ELECTRICAL CLASSIFICATION AS PER N.E.C.AND <br /> C.3 0 BIOSPARGE INJECTION MANIFOLD DETAILS LOCAL CODES. ALL WIRING CONNECTORS,CONDUIT,AND CONTRACTOR <br /> C-4 0 CONCRETE SLAB DETAIL 2.3 CONCRETE MIX DESIGN SPECIFICATION SUPPLIED EQUIPMENT SHALL COMPLY AT A MINIMUM WITH CLASS 1, <br /> C-5 0 TRENCH AND WELLHEAD DETAILS DIVISION It REQUIREMENTS,AS SPECIFIED BY THE N.E.C.OR LOCAL <br /> E-1 0 PANEL AND EQUIPMENT SCHEDULE AND SINGLE LINE 1. A.STRENGTH-3,000 PSI,5-314 BAG MIX CODES. <br /> DIAGRAM B.AGGREGATE SIZE-C2 GRAVEL 314 INCH TO 1 INCH <br /> C.CEMENT TYPE=AND BAG MIX-TYPE 1 PORTLAND CEMENT G. ABOVEGROUND WIRING SHALL BE CONTAINED IN RIGID CONDUIT AND <br /> D,CURE TIME-28 DAYS 90%CURE ROUTEED ALONG THE ENCLOSURE:FLOOR AND-WALLS OR BURIED AS <br /> THIS PACKAGE ALSO CONTAINS THE FOLLOWING SPECIFICATIONS REQUIRED FOR E.SLUMP-MIN 3 INCH,MAX 5-112 INCH ALLOWED BY LOCAL CODE. LIQUID TIGHT FLEX OF UP TO 36 UNCHES IN <br /> CONSTRUCTION AND INSTALLATION: F.MAX TURNS-70 ROTATIONS LENGTH MAY BE USED. <br /> 2.0 SPECIFICATIONS G.MAX TRAVEL TIME-HOT WEATHER 1 HOUR 15 MINUTES,COLD <br /> WEATHER 2 HOURS. 7. ALL ELECTRICAL CONNECTIONS IN SUBSURFACE VAULTS OR PULL BOXES <br /> 2.1 GENERAL SHALL BE COMPLETED AT A MINIMUM IN WATERTIGHT JUNCTION BOXES. <br /> - 1. THE SELECTED CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE <br /> 2.4 PIPING EXPOSED WIRING IS NOT ACCEPTABLE IN VAULTS OR PULL BOXES. <br /> CONDITIONS BEFORE STARTING WORK.THE ENGINEER'S PROJECT 1. ALL UNDERGROUND PROCESS PIPING SHALL BE SDR-17 HDPEUNLESS <br /> MANAGER SHALL BE NOTIFIES] OF ANY DISCREPANCY. ( 2,6 EQUIPMENT <br /> OTHERWISE INDICATED)THREADED TRANSITION FITTINGS, FUSION <br /> 2. ALL MATERIALS USED FOR CONSTRUCTION OF THE SYSTEM SHALL BE WELDS FOR SLIP CONNECTIONS SHALL MEET HDPE PIPE 1. EQUIPMENT TO BE PROVIDED BY THE CONTRACTOR FOR INSTALLATION IS <br /> n. NEW UNLESS OTHERWISE NOTED. MANUFACTURER'S SPECIFICATIONS. ALL ABOVEGROUND PROCESS <br /> INCLUDED ON SHEET P-1(PROCESS AND INSTRUMENTATION DIAGRAM) <br /> 0 3. EQUIPMENT AND INSTRUMENTS THAT ARE SPECIFIED TO BE SUPPLIED BY PIPING SHALL BE SCHEDULE GALVANIZED STEEL(UNLESS OTHERWISE. <br /> AND SHEET 0-2(PIPING AND EQUIPMENT REQUIREMENTS). <br /> INDICATED)WITH THREADEDFI FITTINGS AS INDICATED BY THE:DRAWINGS. <br /> THE ENGINEER WILL BE PROVIDED BY THE ENGINEER FOR INSTALLATION UNLESS OTHERWISE STATED,ALL VALVES SHALL BE THREADED STEEL 2.7 EQUIPMENT ENCLOSURE <br /> BY THE CONTRACTOR UNLESS OTHERWISE NOTED.MATERIALS SHALL BE AS INDICATED BY THE DRAWINGS. 1. CONTRACTOR WILL PROVIDE A SHED ENCLOSURE AS SHOWN ON SHEET <br /> PROVIDED BY THE CONTRACTOR. <br /> ul C-2. THE SHED WILL BE SECURED TO A 9 FEET BY 8 FEET REINFORCED <br /> 2. ALL ABOVEGROUND PIPING SHALL BE PERMANENTLY LABELED AND <br /> 4. ALL NECESSARY CONSTRUCTION PERMITS AND INSPECTIONS SHALL BE PAINTED WITH DIRECTIONAL FLOW ARROWS AND LINE CONTENTS,I.E.: CONCRETE PAD. THE CONCRETE PAD WILL BE 4 INCHES THICK AND <br /> OBTAINED AND PAID FOR BY THE CONTRACTOR,INCLUDING PERMITS AIR, CONSTRUCTED OF 3,000 PSI CONCRETE WITH#4 REBAR AS SHOWN ON <br /> FOR ELECTRICAL,MECHANICAL, AND CIVIL CONSTRUCTION, SHEET C-4, CONTRACTOR WILL BE RESPONSIBLE FOR SECURING THE <br /> 3. WHERE PIPING IS ROUTED ABOVEGROUND INSIDE THE EQUIPMENT SHED TO THE SLAB TO CONFORM WITH CALIFORNIA SEISMIC <br /> 5, THE CONTRACTOR SHALL RESTORE ALL EXCAVATED SURFACE AREAS TO ENCLOSURE,THE PIPING SHALL BE SUPPORTED BY UNI-STRUT PIPE REQUIREMENTS. <br /> MATCH EXISTING. SUPPORTS AND CLAMPS. THE UNI-STRUT SUPPORTS SHALL BE <br /> FASTENED TO THE WALL OR MOUNTED ON A BASE THAT IS SECURED TO 2, CONTRACTOR TO INSTALL THE FOLLOWING SIGNAGE ON THE <br /> 6. ALL CONSTRUCTION AREAS SHALL BE CLEARLY MARKED WITH THE GROUND SURFACE. ENCLOSURE,SEE SHEET C-2 FOR LOCATION OF EACH SIGN: <br /> BARRICADES,CONES, PLATES,OR OTHER APPROVED SAFETY MARKERS <br /> TO RESTRICT ACCESS AND PROVIDE A SAFE WORT(ENVIRONMENT FOR 4. A. DANGER HIGH VOLTAGE <br /> q ALL PROCESS PIPING SHALL BE PRESSURE TESTED ACCORDING TO <br /> S. NO SMOKING <br /> THE CONTRACTOR,STATION CUSTOMERS,AND FUEL TERMINAL LOCAL SPECIFICATIONS AND WITNESSED BY ENGINEER.NO TESTING ' MM WTE osc + <br /> C. PROPOSITION 85 SIGN <br /> PERSONEL. <br /> WILL BE CONDUCTED THROUGH INSTRUMENTS OR EQUIPMENT, ALL D. NEPA 704 SIGN <br /> 7. A PRE-CONSTRUCTION MEETING BETWEEN SITE OWNER,THE LINES WILL BE PRESSURE TESTED AT A MINIMUM PRESSURE OF 15 PSI E. EMERGENCY SHUTOFF SIGN <br /> CONTRACTOR,AND ENGINEER WILL BE REQUIRED BEFORE ANY WORK FOR MINUMUM 1 HOUR,WITH ZERO PERMITTED DROP IN PRESSURE OVER F. EMERGENCY CONTACT INFO <br /> BEGINS.THE MEETING WILL BE HELD AT THE SITE, THE DURATION OF THE TEST. G. EYEWASH SIGN <br /> 8. THE CONTRACTOR SHALL PROVIDE A TECHNICIAN OR EQUIVALENT FOR 4 5. THE CONTRACTOR WILL ID ALL WELL MANIFOLD PIPING USING STEEL 3. CONTRACTOR TO SUPPLY AND INSTALL A FIRE EXTINGUISHER IN AN ALL <br /> $ HOURS DURING STARTUP OF THE EQUIPMENT. TAGS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO STAMP THE WEATHER FIRE EXTINGUISHER CABINET AND IN ACCORDANCE;WITH <br /> APPROPRIATE WELL ID'S ON THE STEEL TAGS AND ATTACH THE TAGS LOCAL FIRE CODES, CONTRACTOR TO SUPPLY MINIMUM 20 POUND ABC <br /> E 9. THE CONTRACTOR SHALL WARRANTY ALL MATERIALS AND WITH CHAINS TO THE CORRESPONDING WELLS AT THE MANIFOLD. FIRE EXTINGUISHER, PROJECT TITLE <br /> F� CONSTRUCTION FOR A PERIOD OF ONE YEAR.ALL DEFECTS SHALL BE <br /> CORRECTED AT THE CONTRACTOR'S EXPENSE. 2,5 ELECTRICAL 4. CONTRACTOR TO SUPPLY AND INSTALL EYEWASH KIT,YELLOW WALL <br /> r j MOUNT STORAGE BOX,ItNOX PADLOCK,FIRE BLANKET,AND FIRST AlbAF Arm <br /> 10. ALL WORK SHALL BE CONDUCTED UNDER CHEVRON'S"PERMIT TO WORK" 1. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL EQUIPMENT KIT. sm <br /> SYSTEM. NO WORK SHALL HE CONDUCTED WITHOUT A PERMIT TO WORK. NECESSARY TO INSTALL A NEW ELECTRIC SERVICE AND ROUTE THE nw.w 63-m om <br /> o APPROPRIATE ELECTRIC SERVICE:TO THE REMEDIATION SYSTEM AND <br /> o 2.2 EXCAVATION REMEDIATION CONTROL PANELS. THE CONTRACTOR WILL BE <br /> RESPONSIBLE FOR PROVIDING POWER TO THE BIOSPARGE TREATMENT BIOSPARGE TREATMENT SYSTEM <br /> 1. ALL EXCAVATED SOIL SHALL BE STOCKPILED ON G-THOUSANTHS OF AN SYSTEM AND OBTAINING ANY REQUIRES)ELECTRICAL PERMIT FOR BANTA BULK FUEL TERMINAL <br /> E INCH(6-MIL)PLASTIC ViSQUEEN UNTIL IT IS USED TO BACKFILL OPERATION OF THE EQUIPMENT, THE CONTRACTOR SHALL VERIFY 22888 KASSON ROAD <br /> t F z1 TRENCHES. SOIL SHALL BE KEPT MOIST TO CONTROL DUST AND MUST BE OPERATION or ALL ELECTRICAL EQUIPMENT UPON COMPLETION OF THE <br /> F COVERED IF LEFT STOCKPILED OVERNIGHT. EARTHEN MATERIALS SHALL WORK, ESS1p BANTA, CALIFORNIA�p <br /> 0 o NOT BE USED TO SECURE THE PLASTIC LINERS OR COVERS.IF 'Y` SHEET TIRE <br /> 2. THE CONTRACTOR SHALL ACQUIRE ALL NECESSARY PERMITS AND PAY S <br /> SEGREGATED <br /> S <br /> HYDROCARBON-IMPACTED SOIL IS AN AREAD,THE SOIL SHALL BE ALL ASSOCIATED FEES INCLUDING CONNECTION AND DISCONNECTION <br /> SEGREGATED AND STOCKPILED IN ST AREA DESIGNATED BY THE !. y, i�j CONSTRUCTION NOTES <br /> ENGINEER AND COVERED WITH PLASTIC SHEETS IF NECESSARY. THE <br /> FEES. THE CONTRACTOR SHALL PAY FOR POWER POLE INSTALLATION AND SPECIFICATIONS <br /> _ ENGINEER WILL BE RESPONSIBLE FOR CHARACTERIZING AND DISPOSING DEPOSIT. c pFn <br /> OF ANY IMPACTED SOIL THAT IS ENCOUNTEREb, THE CONTRACTOR 3. THE ELECTRIC SERVICE SHALL BE EQUIPPED WITH A POWER METER AND NO.046643 <br /> SHALL DISPOSE OF ALL CONSTRUCTION DEBRIS AND SOIL NOT USED FOR WEATHER-TIGHT MAIN PANEL WITH A LOCKA13LE SHUTOFF SWITCH Exp 9102 <br /> BACKFILLING TRENCHING. LOCATED OUTSIDE THE EQUIPMENT ENCLOSURE. 01 <br /> PROJECT MANAGER DEPARTMENT MANAGER <br /> 2, WHERE PIPING IS INSTALLED BELOW GROUND,THE PIPE SHALL BE D. EVANS J.VOGELEY <br /> 1 Ni BURIED IN A TRENCH EXCAVATED TO A MINIMUM DEPTH OF 24 INCHES ��pA o CIM,r LP. WAIJ EAD DESIGNPROF CHECCHECKED BY TO THE TOP OF'THE PIPE, UNLESS OTHERWISE STATED. IF EXCAVATIONS /��y <br /> MUST REMAIN OPEN AFTER NORMAL WORK HOURS,THEY SHALL BE iJ TISK/PHASE HUMBER DRAWN 9Y <br /> J COVERED AT THE CONTRACTOR'S EXPENSE,WITH METAL PLATES `- 00002/0000 DA WALL <br /> (TRENCH PLATES), CAPABLE OF SUPPORTING VEHICULAR TRAFFIC. PROJECT NUMBER DRAWING NUMBER <br /> EXCAVATIONS SHALL NOT REMAIN OPEN OVER A WEEKEND UNLESS GW1A <br /> COVERED BY TRENCH PLATES. 80046293,0000 <br />