Laserfiche WebLink
M <br /> San Joaquin County DIRECTOR <br /> Donna Her an, RENS <br /> Environmental Health Department oA ' c r ASSISTANT DIRECTOR <br /> 600 East Main Street Laurie Cotulla, REHS <br /> Stockton , California 95202 -3029 PROGRAM COORDINATORS <br /> Mike Huggins, REHS, RDI <br /> Margaret Lagorio, REHS <br /> cq</ FORc Website: www. sjgov. org/ehd Robert McClellon, REHS <br /> q Phone : (209) 468-3420 Jeff Carruesco, REHS, RDI <br /> Fax: (209) 464=0138 Kasey Foley, REHS <br /> March 31 , 2009 <br /> Raymond Farmer Enterprises , Inc. <br /> 3810 Fourteen Mile Drive <br /> Stockton , CA 95219 <br /> Subject: Toyota Town Site Code: 1151 <br /> 610 Hunter St <br /> Stockton CA 95202 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed the Monitoring <br /> Report Third Quarter 2008 (QR) dated December 29 , 2008 , Work plan to Conduct a Feasibility <br /> Study for Ozone Pilot Testing (WP) dated August 6 , 2008, and Mass Calculations (MC) dated <br /> January, 22, 2009 , prepared by your consultant ATC Associates Inc. (ATC) for the above <br /> subject site and provides the following comments . <br /> In the WP ATC proposes installation of three ozone sparge wells, performing an ozone sparging <br /> pilot test, conducting a bench scale test if found to be appropriate, and preparation of a <br /> feasibility report. The EHD approves of conducting the bench scale test and requires it be <br /> conducted prior to installation of ozone sparge wells and conducting a field pilot study test. The <br /> bench scale test is used to determine the effectiveness of ozone in treating the contaminant and <br /> evaluate if byproducts or breakdown products may be formed in the reaction of ozone with any <br /> naturally occurring metals or minerals in the soil or groundwater. Since the EHD does not <br /> approve of the installation of the proposed ozone sparge wells at this time, a work plan must be <br /> submitted that includes proposed soil and ground water sample locations and the number of <br /> samples to be collected for conducting the bench scale bench test. This work plan should be <br /> submitted within 60 days of the date of this letter. <br /> In the QR, ATC recommends reducing the frequency of groundwater monitoring sampling in <br /> selected monitoring wells to semi-annual . The EHD approves of reducing the groundwater <br /> sampling schedule as follows until a groundwater remediation system is operated at this site: <br /> MW-4, MW-5, MW-6, MW-8 , MW-9 , and MW-10 sampled biennially; MW-7 sampled annually; <br /> MW- 1 , MW-2 , and MW-3 sampled semi-annually; and discontinuation of sampling Canapa's <br /> Well (MW-4) . Prior to operation of a groundwater remediation system , a new sampling <br /> schedule must be proposed and approved . <br /> If you have any questions , please contact Frank Girardi , at (209) 953-7868 . <br /> AJot� � <br /> Frank Girardi, RENS Marga�o , RE <br /> Senior Registered Environmental Health Specialist Program Coordinator <br /> cc: Jeanne Homsey, ATC Associates Inc. , 1117 Line Palm Avenue Ste 201 , Modesto, CA <br /> 95351 <br /> James Barton, CVRWQCB <br />