MONIT%RING SYSTEM CERTIPWATION <br /> MAKE / MODEL. OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION / TEST DATE: August 1, 2006 <br /> Al. FACILITY A2. OWNER <br /> Name 99 Shell Name Angle Enterprises <br /> Address 7700 Moreland Court, Stockton,CA 95212 Address 35584 Conavan Lane, Fremont,CA 94536 <br /> Phone# 209-939-1906 Phone# 510-552-4822 <br /> Contact Balaji Angle Contact Balaji Angle <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 304 E Weber Avenue,3rd Floor,Stockton,CA 95202 Address P.O. Box 1025.W.Sacramento, CA 95691 <br /> Notified July 24, 2006 Lic# 617238 A, B. Haz <br /> Inspector Lori J. Luces Contact Richard Walton <br /> Phone# 209-468-9847 Phone# 916-825-3203 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> B1: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-91 <br /> ■ In-Tank Gauging Probe Model: 0847390-109 ■ In-Tank Gauging Probe Model: 0847390-109 <br /> ■ Annular Space or Vault Sensor Model: 0794380303 ■ Annular Space or Vault Sensor Model: 0794380-303 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ■ Fill Sump Sensor(s) Model: 0794380-208 ■ Fill Sump Sensor(s) Model: 0794380-208 <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ■ Electronic Line Leak Detector Model: 0848480-001 ■ Electronic Line Leak Detector Model: 0848480-001 <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ■ Other (specify equipment in Section E) Model: ■ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Diesel Tank#4 (Product): <br /> ■ In-Tank Gauging Probe Model: 0847390-109 I ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380.208 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ■ Fill Sump Sensor(s) Model: 0794380-208 ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ■ Electronic Line Leak Detector Model: 0848480-001 ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ■ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> 62: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chains) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5-6 Dispenser#: 7-8 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Vent box Dispenser#: <br /> ■ Dispenser Containment Sensor(s) Model: 0794380.208 ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> ���y!� WALTON <br /> Signature: '�` ENGINEERING,INC. <br /> Technician/Cert#: Bruce N.Stewart / A31131 5249892-UT Date: August 1, 2006 <br /> 2006 Walton Engineering,Inc. <br />