Laserfiche WebLink
Ak <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.siaov.orglehd <br /> Underground Storage Tank Program inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOKP.Y SHELL' 420 W ` 20. 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply( <br /> Item# Remarks <br /> i u6 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EI oe monitoring plan for the gas and diesel <br /> tanks indicates"Yes"for UDC Monitoring Stops Flow of Product at Dispenser. This should be marked as"No". <br /> The monitoring plan for the diesel tank lists MLLD Manufacturer Red Jacket MLLD Model FX IV D. Manufacturer <br /> should be listed as VMI and Model should be listed at 99LD2000. <br /> The monitoring plan for the used oil tank indicated Periodic System Testing"Yes"for Secondary Containment <br /> Testing. This should be listed as"No". <br /> The monitoring plan for the used oil tank lists Leak Sensor Model#302. This should be listed as 301. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> The response plan is not current andfor not approved by the EHD. Section V. of the response plan has not been <br /> completed. The completed response plan must be uploaded to the California Environmental Reporting System <br /> (CERS). Immediately log into CERS, upload the completed form, and submit for review by the EHD. Ensure a copy <br /> is available for inspection at any time. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/sfte map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site plan does not indicated the line leak detectors.A <br /> site plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.Ga.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a minor violation. <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was performed on 1-19-15 and a test report was submitted on 4-10-15, more than <br /> 30 days after the test. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 1-20-15 <br /> and a test report was submitted on 3-30-15, more than 30 days after the test. A copy of the test report must be <br /> submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br /> are performed in a timely manner. <br /> s is a repeat violation, Class II. <br /> Received by Inspector: hone: ate: <br /> (initiall: ARIS VELOSO, Senior RENS (209)468-3453 01/20/2016 <br /> Page 4 of 6 <br />