San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.smaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOKAY SHELL* 420 W KETTLEMAN LN, LODI January 17, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. Section V has not been completed. The <br /> response plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br /> CERS, upload the completed form, and submit for review by the EHD. Ensure a copy is available for inspection at <br /> any time. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site plan does not indicate the line leak detectors <br /> and does not indicate the annular sensor for the diesel/100 octane tanks. A site plan must be submitted identifying <br /> the locations where monitoring will be performed. Immediately log into the California Environmental Reporting <br /> System(CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days. <br /> New designated operators, James Williams and Derreq Knoules, were hired in November 2016 and notification was <br /> not provided to the EHD within 30 days of the change. Any changes shall be reported to the EHD within 30 days. <br /> Immediately log into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov and upload <br /> the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and list the used oil tank on the 11/30/16 designated operator monthly <br /> inspection report and failed to list two tanks and two dispensers on the 12/21/16 designated operator monthly <br /> inspection report.. During the monthly inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class ll. <br /> FA0003776 PR0231906 SCO01 01/17/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />