City of Stocktion A68101.02F <br /> July 24, 1997 Page A-4 <br /> ■ Matrix spikes are analyzed in duplicate to validate the accuracy and precision <br /> of the method; and <br /> ■ During groundwater sampling, a travel blank sample consisting of organic-free <br /> water is prepared and containerized in the laboratory, transported to the site, <br /> and handled and transported in the same manner as the groundwater samples. <br /> A-5 Standard Qperating OperatingProcedures for Using Photoionization Detector PID and/or <br /> Drager® Tubes: The PID is calibrated in accordance with the manufacture's <br /> recommendations prior to use in the field. Upon arrival at the project site, the PID is used <br /> to monitor background concentrations of organic vapors in the atmosphere at the site. The <br /> background concentrations are measured in a location upwind and removed as possible from <br /> sources of organic vapors on the site. When background concentrations of organic vapors <br /> register as "0.0" on the PID, subsequent readings of"0.0" registered from samples tested in <br /> the field are recorded as "ND" (not detected). When background concentrations of organic <br /> vapors register at some quantity above "0.0", subsequent readings registered from samples <br /> tested in the field at or below this value are recorded as "B/G" (background). <br /> The Drager® tubes used is consistent with the type of analyte which is suspected as being <br /> present on the project site (i.e. for gasoline product use the benzene tube, for diesel product <br /> use the petrol-hydrocarbon tube, etc.). Prior to use the tubes are examined to insure the <br /> shelf life expiration date has not expired and the tube has not been opened or damaged. <br /> ' Tubes are only used for one test. The Drager® Gas Detector Pump are used with Drager® <br /> tubes to insure accuracy. Prior to use the pump is examined to insure it is in proper <br /> operating condition. <br /> The tube is opened and inserted into the pump just prior to use. The pump is stroked the <br /> number of times required by the specific tube in use (i.e. 2 strokes for the petrol- <br /> hydrocarbon tube). After each stroke• the pump is allowed to open to the full extent of the <br /> arrestor chain (10 to 20 seconds). <br /> If the analyte is present in the sample, the material within the tube will discolor. The extent <br /> of the discolored material corresponds to the concentration of the analyte present. Readings <br /> from the tube are recorded based upon the amount of discolored material read from the <br /> calibrated markings on the tube. In the event the discoloration should extend beyond one <br /> marking but not to the next, this is recorded as "greater than (>)" the lower value. (i.e. if <br /> the discoloration extends beyond 300 parts per million (ppm) but does not reach 500 ppm, <br /> this would be recorded as >300 ppm). The exception to this is when the discoloration reads <br /> less than the lowest value, this is recorded as "less than (<)" the lowest value on the tube. <br /> After use tubes are disposed of as hazardous material because the contents are corrosive <br /> and the broken glass tip is a cut hazard. <br />