My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_LIMITED PHASE 2 SOIL REPORT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOOPER
>
23
>
2900 - Site Mitigation Program
>
PR0538761
>
ARCHIVED REPORTS_LIMITED PHASE 2 SOIL REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:32:20 PM
Creation date
2/12/2020 9:24:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LIMITED PHASE 2 SOIL REPORT
RECORD_ID
PR0538761
PE
2950
FACILITY_ID
FA0022259
FACILITY_NAME
PORT OF STOCKTON, ROUGH & READY
STREET_NUMBER
23
STREET_NAME
HOOPER
STREET_TYPE
DR
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
01
SITE_LOCATION
23 HOOPER DR
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
331
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Case Narrative C <br /> Client:Antea USA, Inc. TestAmerica Job ID: 720-56810-1 <br /> Project/Site: UPRR-Stockton <br /> Job ID: 720-56810-1 <br /> Laboratory:TestAmerica Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-56810-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 4/16/2014 6:05 PM;the samples arrived in good condition,properly preserved and,where required,on ice. <br /> The temperatures of the 2 coolers at receipt time were 2.0°C and 3.8°C. <br /> GC/MS VOA <br /> Method 8260B: Internal standard responses were outside of acceptance limits for the following sample 56810-3 and confirmed by <br /> ms/msd. The sample shows evidence of matrix interference. <br /> Method 8260B:The matrix spike/matrix spike duplicate(MS/MSD)recoveries and precision for batch#157551 were outside control limits. <br /> Sample matrix interference and/or non-homogeneity are suspected because the associated laboratory control sample/laboratory sample <br /> control duplicate(LCS/LCSD)precision was within acceptance limits. <br /> Method 8260B:The continuing calibration verification(CCV)associated with batch#157641 recovered above the upper control limit for <br /> 2,2-DCPA. The samples associated with this CCV were non-detects for the affected analytes;therefore,the data have been reported. The <br /> following samples are impacted: (CCVIS 720-157641/2). <br /> Method 8260B:The matrix spike/matrix spike duplicate(MS/MSD)recoveries and precision for batch#157641 were outside control limits. <br /> Sample matrix interference and/or non-homogeneity are suspected because the associated laboratory control sample/laboratory sample <br /> control duplicate(LCS/LCSD)precision was within acceptance limits. <br /> Method 8260B: Internal standard responses were lower outside of acceptance limits for the following sample 56810-14 and confirmed by <br /> MS/MSD. The sample shows evidence of matrix interference. <br /> Method 8260B: Internal standard responses were outside of acceptance limits for the following samples: B-27D1.5(720-56810-38), <br /> B-27D4.5(720-56810-39). The samples shows evidence of matrix interference. <br /> Method 8260B: Internal standard responses were lower outside of acceptance limits for the following samples <br /> 56810-23,24,25,26,27,29,30,32,34,37 and samples were ND. The samples show evidence of matrix interference. <br /> Method 8260B:The continuing calibration verification(CCV)associated with batch#157833 recovered above the upper control limit for <br /> 2,2-DCPA,CARBON TETRACHLORIDE. The samples associated with this CCV were non-detects for the affected analytes;therefore,the <br /> data have been reported. The following samples are impacted: (CCVIS 720-157833/10). <br /> Method 8260B:The laboratory control sample duplicate(LCSD)for batch#157833 recovered outside control limits for the following <br /> analytes:T-1,3-DCPE. These analytes were biased high in the LCS and were not detected in the associated samples;therefore,the data <br /> have been reported. <br /> Method 8260B: Internal standard responses were lower outside of acceptance limits for the following sample 56810-4,5,8,10,11,13, <br /> 16,17,18,2-,21 and#22 confirmed by reanalysis and sample were ND. The samples show evidence of matrix interference. <br /> Method 8260B:There was Methylene chloride detection in the sample 56810-13,18, 19 due to lab contamination. <br /> Method 8260B:Surrogate recovery for the following sample was outside the upper control limit:B-8D1.5(720-56810-16). This sample did <br /> not contain any target analytes;therefore,re-extraction and/or re-analysis was not performed. <br /> No other analytical or quality issues were noted. <br /> GC VOA <br /> No analytical or quality issues were noted,other than those described in the Definitions/Glossary page. <br /> TestAmerica Pleasanton <br /> Page 4 of 241 4/29/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.