Laserfiche WebLink
HSite Preparation and Insth. ..tion Instructions <br /> TLS-350 UST Monitoring System <br /> 6. Tighten the cord grip to secure the sensor in position on B.INSTALLATION. <br /> the riser cap and on the junction box to ensure a <br /> water-tight seal at the cable entry. The wires between the monitor and each sump sensor <br /> location must be of a type designed for use in the presence <br /> NOTE: Refer to the tank manufacturer's instruc- of gasoline and oil, and must be between AWG 14 and <br /> tions for setting the proper reservoir brine level. AWG 18. The conduit must be properly sealed in accor- <br /> dance with the National Electrical Code (NFPA70) and <br /> SECTION 9. PIPING SUMP SENSOR the Automotive and Marine Service Station Code(NFPA30) <br /> INSTALLATION since they pass from a Class I, Division I or Division 11 <br /> area into a nonhazardous area. <br /> A.GENERAL. ift WARNING:TO AVOID ELECTRICAL SHOCK <br /> The sump sensor comes with the following hardware WHICH COULD KILL YOU, BE SURE AC <br /> necessary to mount it within the piping sump: POWER TO THE MONITOR IS OFF DURING <br /> 1-PVC Mounting Sleeve INSTALLATION. <br /> 1-Aluminum 900 Mounting Bracket 1. Turn OFF AC power to the TLS-350 system. <br /> 1-Cord Grip CAUTION:DO NOT INSTALL THE SUMP SEN- <br /> 2 -#6-20 (0.312"long)Sheet Metal Screws SOR IF THERE IS ANY LIQUID IN THE PIPING <br /> The sump sensor can be mounted in either of two ways:on SUMP. FAILURE TO COMPLY CAN RESULT IN <br /> the sensor junction box using the mounting bracket and EQUIPMENT DAMAGE OR UNDETECTED PO- <br /> sleeve supplied(see Figure 54,"Typical Bracket Mount"); TENTIAL ENVIRONMENTAL AND HEALTH <br /> or,by cementing the PVC mounting sleeve directly to the HAZARDS. <br /> side of a fiberglass containment sump (see Figure 55, <br /> "Mounting Sleeve Cemented to Sump Wall"). 2. Make sure no liquid exists in the piping sump. <br /> Before you install the sump sensor, t: are are several 3. To mount the sump using the mounting bracket (see <br /> important requirements to consider: Figure 54,"Typical Bracket Mounting"): <br /> 1. The sump sensor must be positioned as close to the a. Attach the mounting bracket to the mounting sleeve <br /> containment sump outer wall as possible. using the two#6-20 0.312"long screws furnished. <br /> 2. The sump sensor must be mounted in a true vertical .1 NOTE:Screw holes drilled in the mounting sleeve <br /> position to ensure proper operation of the float switch are closer to the one end than the other. Check the <br /> contained inside. distance from the top of the junction box to the <br /> bottom of the sump to determine which way you will <br /> 3. There must be at least one inch of clearance between mount the bracket. You must leave some space <br /> the bottom of the mounting sleeve and the base of the between the bottom of the mounting sleeve and the <br /> sump. base of the sump. <br /> 4. When installed,the sump sensor must rest on the base <br /> of the sump. <br /> LEADER CABLE <br /> LEADER CABLE <br /> CORD GRIP SUMP <br /> WALL <br /> CORD GRIP <br /> MOUNTING BRACKET SUMP JUNCTION BOX <br /> WALL <br /> JUNCTION BOX <br /> I I <br /> I I <br /> I I <br /> I <br /> MOUNTING SLEEVE <br /> MOUNTING SLEEVE jai <br /> SUMP SENSOR SWITCH <br /> SUMP SENSOR SWITCH <br /> Figure 54. Typical Bracket Mounting. Figure 55.Mounting Sleeve Cemented to Sump Wall. <br /> 34 <br />