Laserfiche WebLink
` A. <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> °P " ° SAN JOAQUIN COUNTY <br /> Donna K.Heran,R.E.H.S. Unit Supervisors <br /> Director 304 East Weber Avenue, Third Floor Carl Borgman,R.E.H.S. <br /> 1 Al Olsen,R.E.H.S. Stockton, California 95202-2708 Mike Huggins,R.E.H.S.,R.D.I. <br /> Douglas W.Wilson,R.E.H.S. <br /> C`qC,FO.Ra�P Program Manager Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> Laurie A.Cotulla,R.E.H.S. <br /> Program Manager Fax: (209)464-0138 Robert McClellon,R.E.H.S. <br /> April 25, 2005 <br /> Mark Barcellos,R.E.H.S. <br /> Walton Engineering <br /> PO Box 1025 <br /> West Sacramento CA 95691 <br /> Re: 7700 Moreland Court, Stockton <br /> Your application for permit to install a new underground storage tank system at the above location has <br /> been approved with the following conditions: <br /> 1. Contact the fire department and the San Joaquin Valley Air Pollution Control District for <br /> applicable permits. <br /> 2. The contractor shall be licensed by the Contractors Licensing Board. <br /> 3. At least one person who holds the International Code Council (ICC) UST Installer/Retrofitter <br /> certification must be onsite when work is performed. <br /> 4. Any changes shall be submitted to EHD for approval prior to commencing work. All new <br /> submittals supercede the previous ones. <br /> 5. All piping, fittings, sumps, under-dispenser containment and tanks must be certified by an <br /> independent testing organization and labeled as required by the organization. (UL,ULC, ANSI, <br /> API, ASTM ect...See Title 23 Chapter 16 Table B for complete list) <br /> 6. All monitoring systems shall be listed on the LG113-16. <br /> 7. All testing shall be in compliance with manufacturer's instructions, section 2635 and section 2636 <br /> of California Code of Regulations (CCR) <br /> 8. Recommend installing automatic pump shutdown, which will, satisfy CCR 26350. <br /> 9. All piping must slope to a containment sump with an audible/visual alarm. <br /> 10. All connections(shreader valves) from the vacuum on the piping to the vacuum source must be <br /> turned down in the piping sump. <br /> 11. All tank top openings, that are connected to the primary space of the UST must have secondary <br /> containment, audible/visual alarm and be vapor tight or terminate at grade. <br /> 12. Sumps and under dispenser containment must be constructed in a manner to prevent vapors from <br /> entering the backfill. <br /> 13. All secondary containment must be constructed to prevent water intrusion. <br /> 14. The secondary containment system must be continuously monitored as required under California <br /> Health & Safety Code(HSC)25290.1 <br /> 15. Overfill prevention shall satisfy CCR 2635(b)(2)(B). <br /> 16. Underground storage tanks are to be anchored per the permit application. <br /> 17. The tank owner must submit the owner statement and name/ICC certification information for this <br /> facility's, "California UST System Operator" (Designated Operator) prior to the final inspection. <br /> 18. A "Certificate of Compliance for Underground Storage Tank Installation Form C" shall be <br /> submitted by the owner or the owners' agent [pursuant to California Code of Regulation(CCR) <br /> 2635(d)] before this upgrade will be considered complete by SJCEHD. <br /> Page 1 of 2 <br />