Laserfiche WebLink
Treadwell&Rollo <br /> ' ten-foot spacing. TC results indicated that two anomalies were present while several VMG <br /> anomalies were detected. <br /> 3.2.2 Soil and Grab Groundwater Sampling <br /> On 14 and 15 September 1999, Precision Sampling, Inc. (Precision) of Richmond, California <br /> used a backhoe to dig exploratory pits and trenches to a depth of 4 to 10 feet at the geophysical <br /> anomalies. Figure 4 shows the TP locations. An additional excavation was located in the central <br /> portion of the site. This area was excavated to a depth of 10 feet bgs. Buried metal, construction <br /> debris, and utility lines were encountered in the trenches; however, no evidence of existing USTs <br /> was found. Test pits 2ATP-3 through 5 were excavated to ten feet at the locations shown on <br /> Figure 4. Soil samples were collected at the locations shown on the test pit logs in Appendix C. <br /> ' On 17 September 1999, Precision used the SD-1 direct push rig to collect soil and groundwater <br /> samples. Soil borings 2AB-1, 2AB-2, and 2AB-3 were pushed to a depth of 10 feet and 2AB-4 <br /> wasp ushed to a depth of 52 feet. Soil samples were collected at the depths shown on the boring <br /> ' logs in Appendix C. A groundwater grab sampling was collected at boring 2AB-4. <br /> On 11, 12, and 13 October 1999, THF Drilling,Inc. (THF) of Fontana, California installed <br /> ' monitoring wells under the direction of Treadwell &Rollo. Borings 2AMW-12 through <br /> 2AMW-15 were drilled to depths of approximately 30 feet. Soil samples were collected for <br /> laboratory analysis at the locations shown on boring logs in Appendix C. <br /> 3.2.3 Groundwater Monitoring Well Development and Sampling <br /> On 2 September 1999, Blaine Tech Services Inc. (Blaine Tech) of San Jose, California, collected <br /> groundwater from monitoring wells MW-1, MW-5, MW-6,MW-8, and MW-9 and a duplicate <br /> sample (DUP) from well MW-1. Monitoring wells MW-2, MW-4 and MW-7 could not be <br /> located and monitoring well MW-3 had been damaged, preventing sampling. <br /> 9 <br /> 25970119.DGD 13 December 1999 <br />