My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING ___ <br /> Test Method Developed By: D Sump Manufacturer E9 Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Metliod Used: C Pressure 0 Vacuum Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: INCON TS STS Equipment Resolution: .000 1" <br /> MEN= <br /> -s Sump#87 Sump#91 Sump#DSL Sump# <br /> Sump Diame132 — ._— 32 32 <br /> Sump Depth-.7 30 25 26 <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from'Tank Top to Top of 8 11 7 <br /> Hihest PjLinPenetration: <br /> Height from'Tank Top to Lowest 16 15 7 <br /> Electrical Penetration: <br /> Conditio;a of sump prior to testing: GOOD GOOD GOOD <br /> Portion c.f Sump Tested' 10 13 9 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Yes --,No A NA I :1Yes ❑No gNA Z,Yes C No ji�NA `Yes ❑No ❑NA <br /> product and water?'. <br /> Turbine:;hutdown response time <br /> Is system programmed for fail-safe ❑Yes 7 No 14 NA D Yes ❑No F N.A C Yes ONO RNA C Yes ONO CNA <br /> shutdovw?* <br /> Was fail-safe verified to be ❑Yes No 18 NA ❑Yes ❑No IXNA ❑Yes ❑No INA C Yes C No CNA <br /> operational?* <br /> Wait tim,,between applying <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 1414 1336 1313 <br /> Initial Reading(R4): 7.7027 1.8208 5.4415 <br /> Test End Time: 1430 1352 1328 <br /> Final Reading(RF): 7.7027 1.8199 5.4415 <br /> Test Duration: I hr l hr 1 hr <br /> Change in Reading(RF-Rill 1 0.0000 0.0009 0.0000 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 <br /> Test Result: K Pass ❑Fail Pass ❑Fail Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing'. JYcs ❑No C NA j KYes ❑No CNA KYes C No CNA C Yes C No NA <br /> Was sew,or properly replaced and Yes �,No !!NA ►Yes U No O NA 4Yes D No ❑NA U Yes ❑No U NA <br /> verified f'.mctional after testing? <br /> Comme:nta (Include information ori repairs niade prior to testing, and recommended follow-up fo-fa fled tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to Iy of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.