COMPLIANCE INFO_2005 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 � Page of <br /> 7. _UNDER-DISPENSER CONTAINMENT(UDC) TE7iNG <br /> Test Metaod Developed By: ❑UDC Manufacturer ❑ Industry Standard ❑Professional Engineer <br /> Other(Specify) <br /> Test Met iod Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> C Other(,Spec) <br /> Test Equ'pment Used: INCON TS STS Equipment Rcsolution: .0001" <br /> UDC# 1-; LUDC#3-4 T UDC# <br /> UDC Manufacturer: BRAVO BRAVO <br /> UDC Material: FIBERGLASS STEEL <br /> UDC Depth. 37. 11 <br /> Height frim UDC Bottom to Top 17 0 <br /> of M e<,t Piping Penetration: <br /> Height frram UDC Bottom to N/A 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD GOOD <br /> testin : <br /> Portion orLJDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 7-Yes ❑No kNA ❑Yes 0 No SNA 0 Yes C No ❑NA ❑Yes 0 No ❑NA <br /> product end water? <br /> Turbine shutdown response time <br /> Is system.programmed for fail- ❑Yes No ANA 'r--,Yes ❑No �NA ❑Yes ❑No [INA -Yes ❑No ❑NA <br /> safe shub.iowa?' <br /> Was fail- afe verified to be !_:Yes L No TINA -,Yes :!No SNA ❑Yes ❑No DNA ---,Yes C No ❑NA <br /> o erational?* <br /> Wait time between applying <br /> pressure/-;actium/water and <br /> starting test <br /> Test Start.Time: 1544 1434 <br /> R Initial Restdina(R4): 5.1296 1.9226 <br /> r Test End Time: 1559 1449 <br /> Final Rea;d9n g(RF): 5.1298 1.8196 <br /> Test Duration.: 15 min 15 min <br /> Change it Reading(Rr-Rt): 0.0002 0.1030 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result- 9 Pass ❑Fail ❑ Pass &Fail 0.Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensar removed.for testing? Yes ::No ENA ❑Yes -No NA ❑Yes 11 No 0 NA C Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified i rinctional after testing? KYes O No '--NA -._1Yes _No %i NA -Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Comore ItS-(include i7 formation on repairs made prior to testing and recommendedfollow-up for failed tests) <br /> - If the enr.ire depth of the UDC is not tested,specify how much was tested. If the answer to ty of the questions indicated with an <br /> asterisk M is"NO"or`RVA",the entire UDC must be tested. (See SWRCB LG-160) <br />