My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_1985 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:57:00 PM
Creation date
2/19/2020 11:53:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985 - 2004
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
229
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
07/28/2004 15:22 209-577-6040 BOYETT PETROLEUM PAGE 03/1 <br /> .Its of Testing/Servicing <br /> /are Version Installed: <br /> Q <br /> o lete the followingchecklist; <br /> es ❑ No* is the audible alarm operational? <br /> Yes ❑ No* Is the visual alarm operational? <br /> Yes la No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ Ifo" if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> NIA operational? <br /> Yes Cl No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> Cl N/A monitoring system detects a leak, fails to operat °r is electrically disconnected? if yes: which sensors initiate <br /> positive shut-down? (Check all that apply) L5ump/Trench Sensors; ❑ Dispenser�Coninment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? © les; ❑No. <br /> ❑ Yes ❑�Io* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible think <br /> fill point(s)and operating ro erl ? if so,at what percent of tank capacity does the alarm trigger? <br /> ❑ Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E below_ <br /> ❑ Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) El <br /> Product; ❑ Water. If yes,describe causes in Section F below. <br /> es ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set u reports, if applicable <br /> Yes El No* is all monitoringc ui mcnt o erational er manufacturer's s ecifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments- <br /> Page 2 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.