SAN. JOARIN Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Nan.: Facility Address: Date: <br /> JOES TRAVEL PLAZA 15600 SHAR LAN RD, LATHROP February 13, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-NOtic.m Comply) <br /> Item M Remarks <br /> 711 CFR 112.8(cx8)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The SPCC Plan calls for Steel Tank Institute(STI)SP-001 testing on the four 10,000 gallons tanks every 20 years <br /> by a certified SP-001 inspector.The SPCC plan states that the tanks were placed into serves in 1898 and that the <br /> STI certified inspection should have been conducted in 2018.The tanks have not been inspected by a certified <br /> inspector.The the outside of the primary container for the 10,000 gallons tanks is not being inspected for signs of <br /> deterioration,discharges,or accumulation of oil inside diked areas.The annular space of the double walled tanks is <br /> not being inspected.The annular space of the double walled tanks have an electronic sensor to alert for the <br /> presence of liquids withing the annular space.An alarm history was provided which shows an alarm in the annular <br /> space of one of the 10,000 gallons diesel tanks on May 18,2018,March 23 and March 25 of 2018 and the alarms <br /> have not been followed up on. <br /> Test or inspect each aboveground container for integrity on a regular schedule and whenever you make material <br /> repairs.You must determine,in accordance with industry standards,the appropriate qualifications for personnel <br /> performing tests and inspections,the frequency and type of testing and inspections,which take into account <br /> container size,configuration,and design (such as containers that are:shop-built,field-erected,skid-mounted, <br /> elevated,equipped with a liner,double-walled,or partially buried). Examples of these integrity tests include, but are <br /> not limited to:visual inspection,hydrostatic testing, radiographic testing, ultrasonic testing,acoustic emissions <br /> testing,or other systems of non-destructive testing.You must keep comparison records and you must also inspect <br /> the container's supports and foundations.In addition,you must frequently inspect the outside of the container for <br /> signs of deterioration,discharges,or accumulation of oil inside diked areas. Records of inspections and tests kept <br /> under usual and customary business practices satisfy the recordkeeping requirements of this paragraph. <br /> Test or inspect all tanks as required by the SPCC plan.Submit copies of the inspection reports to the EHD. <br /> Amendments to this section will require certification by a Professional Engineer. <br /> This is a repeat violation,Class If. <br /> 715 CFR 112.8(cx8)(v)Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> Liquid level sensing devices have not been tested for the 10,000 gallon tanks. <br /> Procedures and frequency of testing for these devices were not addressed in the Spill Prevention,Control,and <br /> Countermeasure(SPCC)plan. <br /> Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be regularly tested to ensure <br /> proper operation. Immediately conduct all necessary testing of liquid level sensing devices,or provide equivalence <br /> as allowed by CFR 112.7(ax2). <br /> This is a Class II violation. <br /> FM000174 PR0515GM 50001 02132021 <br /> IaD1801 Rcr.&S0ci018 Page 7 of AI­A,,JPtlr SIWa AC OIR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 4840138 1 wwwajoehd.com <br />