EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
10173
>
2600 - Land Use Program
>
PA-1700196
>
SU0013032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2020 8:36:30 AM
Creation date
2/25/2020 10:16:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013032
PE
2631
FACILITY_NAME
PA-1700196
STREET_NUMBER
10173
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220-
APN
01718012
ENTERED_DATE
2/20/2020 12:00:00 AM
SITE_LOCATION
10173 E ACAMPO RD
RECEIVED_DATE
2/18/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sshih
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin Ordinance requirements will be applicable to the proposed project . The <br /> following conditions shall be addressed prior to submittal of a building permit application <br /> to the Building Inspection Division : <br /> 1 ) A building permit for each separate structure or building is required . Submit plans , <br /> Specifications and supporting calculations , prepared by a Registered Design <br /> Professional ( architect or engineer ) for each structure or building , showing compliance <br /> with The 2016 California Building , Existing Building , Mechanical , Plumbing , Electrical , <br /> Energy and Fire Codes as may be applicable . Plans for the different buildings or <br /> structures may -be combined into a single set of construction documents . <br /> 2 ) A grading permit will be required for this project . Submit plans and grading <br /> calculations , including a statement of-the estimated quantities of excavation and fill , <br /> prepared by a Registered Design Professional . The grading plan shall show the <br /> existing grade and finished grade in contour intervals of sufficient clarity to indicate the <br /> nature and extent of the work and show in detail that it complies with the requirements <br /> of the code . The plans shall show the existing grade on adjoining properties in <br /> sufficient detail to identify how grade changes with conform to the requirements of the <br /> code . <br /> 3 ) The required plans must be completed at the time of submittal for a building permit . <br /> Plans must address building design and construction , fire and life safety requirements , <br /> accessibility and show compliance with th _ current California codes a-nd San Joaquin <br /> County ordinances . A complete set of plans must include fire sprinkler plans , truss <br /> design submittals , metal building shop drawings , structural plans and calculations , <br /> plumbing , electrical and mechanical drawings and energy report . <br /> 4 ) For each proposed new building , provide the following information on the plans : <br /> ( a ) Description of proposed use <br /> ( b ) Existing and - proposed oc-cupancy Groups- <br /> ( c ) Type of construction <br /> ( d ) Sprinklers ( Yes or No ) <br /> ( e ) Number of stories <br /> ( f) Building height <br /> ( g ) Allowable floor area <br /> ( h ) Proposed floor area <br /> ( i ) Occupant load based on CBC <br /> (j ) Occupant load based on CPC <br /> 5 ) Phase 1 proposed a new 4 , 224- square400t mixed - occupancy wine production <br /> marketing event area ( Area F , 3 , 200 square feet )/ storage- ( Area H , 1 , 024 square feet ) <br /> building with a 2 , 048 - square -foot second level identified as a " mezzanine . " However , <br /> the second level area exceeds the area allowed for a mezzanine , which is limited to <br /> not more than one - third the floor area of the room or space in which it is located ( CBC <br /> 505 . 2 . 1 ) . This second level must be reduced in size or analyzed as a second floor . <br /> The building must be analyzed as a mixed occupancy building per CBC section 508 . <br /> 6 ) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix <br /> § J104 for grading . All recommendation of the Soils Report shall be incorporated into <br /> the construction drawings . <br /> PA- 1700196 — Updated Conditions of Approval 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.