Laserfiche WebLink
ABBREVIATIONS <br />& <br />AND <br />I.D. <br />INSIDE DIAMETER <br />L <br />ANGLE <br />INSUL. <br />INSULATION <br />@ <br />AT <br />INT. <br />INTERIOR <br />q <br />CENTERLINE <br />JT, <br />JOINT <br />0 <br />DIAMETER OF ROUND <br />KIT. <br />KITCHEN <br /># <br />POUND OR NUMBER <br />LAM. <br />LAMINATE <br />(E) <br />EXISTING <br />LAV. <br />LAVATORY <br />(R) <br />RELOCATED <br />LT. <br />LIGHT <br />PER CPC 422.1 <br />CIVIL - NOTES AND DETAILS <br />L.E.D. <br />LIGHT EMITTING DIODE <br />(N) <br />NEW <br />MAX. <br />MAXIMUM <br />A.F.F. <br />ABOVE FINISH FLOOR <br />M.C. <br />MEDICINE CABINET <br />A.D. <br />AREA DRAIN <br />MECH. <br />MECHANICAL <br />ADJ. <br />ADJUSTABLE <br />MEMB. <br />MEMBRANE <br />AGGR. <br />AGGREGATE <br />MTL. <br />METAL <br />AL. <br />ALUMINUM <br />MFR. <br />MANUFACTURER <br />APPROX. <br />APPROXIMATE <br />MIN. <br />MINIMUM <br />ARCH. <br />ARCHITECTURAL <br />MIR. <br />MIRROR <br />ASB. <br />ASBESTOS <br />MISC. <br />MISCELLANEOUS <br />ASPH. <br />ASPHALT <br />M.O. <br />MASONRY OPENING <br />BD. <br />BOARD <br />MTD- <br />MOUNTED <br />BITUM. <br />BITUMINOUS <br />MUL, <br />MULLION <br />BLDG. <br />BUILDING <br />N. <br />NORTH <br />BLKG. <br />BLOCKING <br />N.I.C. <br />NOT IN CONTRACT <br />BM <br />BEAM <br />NO. OR <br />NUMBER <br />BOT. <br />BOTTOM <br />NOM. <br />NOMINAL <br />CAB <br />CABINET <br />N.T.S. <br />NOT TO SCALE <br />CEM. <br />CEMENT <br />O.A. <br />OVERALL <br />CER. <br />CERAMIC <br />OBS. <br />OBSCURE <br />C. 1. <br />CAST IRON <br />O.C. <br />ON CENTER <br />CLG. <br />CEILING <br />O.D. <br />OUTSIDE DIAMETER <br />CLKG. <br />CAULKING <br />OFF. <br />OFFICE <br />CLO. <br />CLOSET <br />OPNG, <br />OPENING <br />CLR./CL, <br />CLEAR <br />OPP. <br />OPPOSITE <br />C.O. <br />CASED OPENING <br />PL. <br />PLATE <br />COL. <br />COLUMN <br />P.LAM. <br />PLASTIC LAMINATE <br />CONC, <br />CONCRETE <br />PLAS. <br />PLASTER <br />CONN. <br />CONNECTION <br />PLYWD. <br />PLYWOOD <br />CONSTR. <br />CONSTRUCTION <br />PR. <br />PAIR <br />CONT. <br />CONTINUOUS <br />PT. <br />POINT <br />CTSK. <br />COUNTERSUNK <br />PTN. <br />PARTITION <br />CNTR. <br />COUNTER <br />Q.T. <br />QUARRY TILE <br />CTR. <br />CENTER <br />QSR <br />QUICK SERVE RESTAURANT <br />DBL <br />DOUBLE <br />R OR RAD. <br />RADIUS <br />DEPT. <br />DEPARTMENT <br />R.D. <br />ROOF DRAIN <br />DET. <br />DETAIL <br />REF, <br />REFERENCE <br />DIA. <br />DIAMETER <br />REFR. <br />REFRIGERATOR <br />DIM, <br />DIMENSION <br />RGTR. <br />REGISTER <br />DISP. <br />DISPENSER <br />REINF. <br />REINFORCED <br />DN. <br />DOWN <br />REQ'D <br />REQUIRED <br />D.O. <br />DOOR OPENING <br />RESIL. <br />RESILIENT <br />DR. <br />DOOR <br />RM. <br />ROOM <br />DWR. <br />DRAWER <br />R.O. <br />ROUGH OPENING <br />D.S. <br />DOWNSPOUT <br />R.W,L. <br />RAIN WATER LEADER <br />DWG. <br />DRAWING <br />S. <br />SOUTH <br />E <br />EAST <br />S.C. <br />SOLID CORE <br />EA <br />EACH <br />SCHED. <br />SCHEDULE <br />E.J. <br />EXPANSION JOINT <br />S.D. <br />SOAP DISPENSER <br />EL. <br />ELEVATION <br />SECT. <br />SECTION <br />ELEC. <br />ELECTRICAL <br />SH. <br />SHELF <br />E.P. <br />ELECTRICAL PANELBOARD <br />SHR, <br />SHOWER <br />EQ <br />EQUAL <br />SHT. <br />SHEET <br />EQPT. <br />EQUIPMENT <br />SIM. <br />SIMILAR <br />EXST. <br />EXISTING <br />SPEC. <br />SPECIFICATION <br />EXP. <br />EXPANSION <br />SQ. <br />SQUARE <br />EXT. <br />EXTERIOR <br />S.S. <br />STAINLESS STEEL <br />F.E. <br />FIRE EXTINGUISHER <br />STD. <br />STANDARD <br />F.F. <br />FLOOR FINISH <br />STL. <br />STEEL <br />FDN. <br />FOUNDATION <br />STOR• <br />STORAGE <br />FIN. <br />FINISH <br />STRL. <br />STRUCTURAL <br />FL. <br />FLOOR <br />SYM. <br />SYMMETRICAL <br />FLASH'G <br />FLASHING <br />T.B.S. <br />TO BE SPECIFIED <br />FLUOR. <br />FLUORESCENT <br />TRD <br />TREAD <br />F.O.C. <br />FACE OF CONCRETE <br />T.B. <br />TOWEL BAR <br />F.O.F. <br />FACE OF FINISH <br />T.C. <br />TOP OF CURB <br />F.O.S. <br />FACE OF STUD <br />TEL. <br />TELEPHONE <br />FPRF. <br />FIREPROOF <br />TER. <br />TERRAllO <br />F.S. <br />FLOOR SINK <br />T&G <br />TONGUE & GROOVE <br />FT. <br />FOOT OR FEET <br />THK. <br />THICK <br />FTG. <br />FOOTING <br />T. P. <br />TOP OF PAVEMENT <br />FURR. <br />FURRING <br />T.P.D. <br />TOILET PAPER DISPENSER <br />FUT. <br />FUTURE <br />T.V. <br />TELEVISION <br />G.A. <br />GAUGE <br />T.W. <br />TOP OF WALL <br />GALV. <br />GALVANIZED <br />TYP, <br />TYPICAL <br />GL. <br />GLASS <br />UNF. <br />UNFINISHED <br />GR. <br />GRADE <br />U.N.O. <br />UNLESS NOTED OTHERWISE <br />GSM <br />GALVANIZED SHEET METAL <br />VERT. <br />VERTICAL <br />GYP. <br />GYPSUM <br />V.C.T. <br />VINYL COMPOSITE TILE <br />G.W.B. <br />GYPSUM WALL BOARD <br />W. <br />WEST <br />H.B. <br />HOSE BIBB <br />W/ <br />WITH <br />H.C. <br />HOLLOW CORE <br />WB. <br />WALL BASE <br />HDWD. <br />HARDWOOD <br />W.C. <br />WATER CLOSET <br />HDWE, <br />HARDWARE <br />WD. <br />WOOD <br />H.M. <br />HOLLOW METAL <br />W/0 <br />WITHOUT <br />HORIZ. <br />HORIZONTAL <br />HR. <br />HOUR <br />WP. <br />WATERPROOF <br />HT. <br />HEIGHT <br />WSCT. <br />WAINSCOT <br />WT. <br />WEIGHT <br />SYMBOLS <br />SECTION MARK XX <br />xx.x <br />EXTERIOR ELEVATION TAG XX <br />XX.X <br />X <br />ELEVAT ON TAG X XX.X X <br />X <br />ELEVATION MARK LOCAT ON <br />FINISH TAG XX -X <br />WINDOW TAG OX <br />DOOR TAG 0 <br />WALL TAG XX <br />KEYED NOTE XX <br />ARCO <br />ARCO AM/PM <br />NWC CHEROKEE RD <br />@ NEWTON RD <br />STOCKTON, CALIFORNIA <br />GENERAL PROJECT NOTES <br />1. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL <br />RESTRICTIONS. CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION <br />REQUIREMENTS OF ALL GOVERNING AUTHORITIES. THE GENERAL BUILDING PERMITS <br />SHALL BE PAID FOR BY THE OWNER UNLESS AGREED OTHERWISE. ALL OTHER PERMITS <br />SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. <br />ALL REQUIRED CITY, COUNTY AND/OR STATE LICENSES SHALL BE ACQUIRED AND PAID <br />FOR BY THE INDIVIDUAL SUBCONTRACTOR. <br />2. IT IS THE INTENT OF THE OWNER, THE ARCHITECT AND THEIR CONSULTANTS, THAT <br />ALL WORK DEPICTED IN THESE DRAWINGS AND SPECIFICATIONS IS TO BE PROVIDED BY <br />THE GENERAL CONTRACTOR. ANY REFERENCES TO THE CONTRARY THROUGHOUT THE <br />CONSTRUCTION DOCUMENTS OR SPECIFICATIONS IS NOT INTENDED. ADDITIONALLY, <br />CONTRACTOR IS TO REFER TO THE BID DOCUMENT PACKET AND/OR OWNER'S SCOPE <br />OF WORK DOCUMENT(S) WHICH SHALL TAKE PRECEDENCE OVER SCOPE THAT MAY BE <br />PRESENTED IN THIS SET OF CONSTRUCTION DOCUMENTS OR SPECIFICATIONS. THE <br />SCOPE OF WORK DOCUMENT IS INTENDED TO IDENTIFY ALL OWNER SUPPLIED ITEMS <br />OR WORK PROVIDED BY OTHERS. ABSENCE OF THESE DOCUMENTS MEANS ALL WORK <br />NOTED IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR UNLESS THE OWNER <br />HAS SPECIFIED OTHERWISE DURING THE BID PROCESS. <br />3. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY <br />WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION AS THE <br />APPROVED PLANS. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON <br />THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA <br />AND CHANGE ORDERS. <br />4. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND <br />SPECIFICATIONS ARE NOT INTENDED. THE CONTRACTOR IS TO CLARIFY ANY SUCH <br />DISCREPANCIES WITH THE ARCHITECT OR PROJECT MANAGER PRIOR TO COMMENCING <br />WORK. STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE <br />DRAWINGS TO DETERMINE LOCATIONS. THE ARCHITECT OR PROJECT MANAGER SHALL BE <br />NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR TO CONTINUING WITH WORK. <br />5. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL <br />REQUIREMENTS OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE <br />OF CONSTRUCTION AND OCCUPANCY. THE CONTRACTOR SHALL NOTIFY ARCHITECT <br />IMMEDIATELY OF CONFLICTS WITH GOVERNING CODE REQUIREMENTS BEFORE <br />PROCEEDING FURTHER WITH THE AFFECTED WORK. <br />6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING <br />UTILITIES AND TO PROTECT THEM FROM DAMAGE. CONTRACTOR SHALL BEAR THE <br />EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED <br />BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. <br />7. THE CONTRACTOR TO PROVIDE FIRE SPRINKLER SYSTEM AND ALARM SYSTEM (WHEN <br />REQUIRED BY CODE AND NOTED AS REQUIRED BY THESE PLANS) IN ACCORDANCE WITH <br />NFPA REQUIREMENTS. FIRE SPRINKLER CONTRACTOR IS TO SUBMIT COMPLETE SHOP <br />DRAWINGS, LAYOUT AND RELATED DATA TO BUILDING DEPARTMENT AND FIRE MARSHAL <br />FOR APPROVAL PRIOR TO INSTALLATION. <br />8, FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP <br />DRAWINGS/DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. ALL <br />DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br />9. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL FOOD SERVICE EQUIPMENT AND <br />COORDINATE LOCATION OF ALL UTILITIES INCLUDING FLOOR SINKS, FLOOR DRAINS, <br />SLOPES/SLAB DEPRESSIONS AND RAISED CURBS, ELECTRICAL AND PLUMBING AND <br />STUBOUTS FOR FUTURE EQUIPMENT WHERE NOTED. <br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE <br />WHILE JOB IS IN PROGRESS AND UNTIL BUILDING IS OCCUPIED. <br />11. ALL DEBRIS SHALL BE REMOVED FROM PREMISES REGULARLY AND ALL AREAS SHALL <br />BE LEFT 1N A CLEAN (BROOM) CONDITION AT ALL TIMES. <br />12. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF <br />THE OCCUPANTS AND WORKERS AT ALL TIMES. <br />13. CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER, TELEPHONE, FACSIMILE OR <br />METHOD TO RECEIVE E-MAIL, PRINTER AND TOILET FACILITIES AS REQUIRED. <br />14. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UN -CRATING, <br />INSTALLATION AND HOOKUP OF ALL FOOD SERVICE EQUIPMENT AND OTHER OWNER OR <br />VENDOR FURNISHED ITEMS. <br />15. GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, PLUMBING <br />VALVES, AND ROOF TOP EQUIPMENT WITH PLASTIC PHENOLIC ENGRAVED PLATES <br />ATTACHED TO IDENTIFY THE EQUIPMENT USE OR PURPOSE. <br />16. CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK ALL INSERTS, <br />ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND <br />PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK, SPECIAL <br />INSPECTION REQUIREMENTS MAY APPLY TO ALL STRUCTURAL EMBEDMENTS OR POST <br />INSTALLED ANCHORS. CONTRACTOR SHALL CONFIRM REQUIREMENTS PRIOR TO <br />INSTALLATION. <br />17. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE MEANS AND METHODS <br />FOR ERECTION PROCEDURE AND SEQUENCE OF THE CONSTRUCTION. CONTRACTOR TO <br />INSURE THE SAFETY OF ALL INSTALLED IMPROVEMENTS, BUILDINGS AND THEIR <br />COMPONENT PARTS DURING ERECTION. <br />18, MATERIALS LISTED IN DRAWINGS ARE BASED ON DESIGN INTENT. ALTERNATE <br />SPECIFICATIONS MAY BE ACCEPTED PROVIDED THEY CLOSELY MATCH AND ARE DEEMED <br />EQUAL TO SPECIFIED MATERIAL. GENERAL CONTRACTOR IS TO SUBMIT PROPOSED <br />SAMPLES OF SUBSTITUTIONS, ALONG WITH SAMPLE OF THAT SPECIFIED IN DRAWINGS <br />FOR REVIEW BY THE ARCHITECT OR PROJECT MANAGER. SUBSTITUTIONS WILL ONLY BE <br />APPROVED IF SPECIFIED MATERIAL IS PROVEN TO BE UNAVAILABLE WITHIN A <br />REASONABLE TIME FRAME OR THE SUBSTITUTION IS A BENEFIT TO THE OWNER RELATED <br />TO COST OR SCHEDULE TIME SAVINGS. <br />19. THE PROJECT BOUNDARIES SHALL BE CONFIRMED BY THE CONTRACTOR PRIOR TO <br />CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE OWNERS ATTENTION <br />IMMEDIATELY BEFORE PROCEEDING WITH CONSTRUCTION. <br />20. ALL LABOR, MATERIALS AND INSTALLATIONS MUST COMPLY WITH THE CODES AND <br />REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCY WHICH <br />EXISTS BETWEEN THE REQUIREMENTS BY THE PLANS, SPECIFICATIONS, SAID CODES, <br />RULES AND REGULATIONS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF <br />THE ARCHITECT, IN WRITING FOR RESOLUTION. IF ANY CHANGE IN THE PLANS AND / <br />OR SPECIFICATIONS OCCURS AS A RESULT OF THE REQUIREMENTS OF THE LIFE <br />SAFETY CODE (NFPA 101) OR ANY OTHER AUTHORITIES HAVING JURISDICTION AFTER <br />THE SUBMISSION OF BIDS, THEN THE BIDDERS WILL BE GIVEN THE OPPORTUNITY TO <br />ADJUST THEIR BIDS, IF NECESSARY, ONLY FOR THE CHANGE. <br />21. THE CONTRACTOR SHALL COORDINATE THE WORK WITH MECHANICAL, ELECTRICAL AND <br />PLUMBING DRAWINGS FOR ALL NECESSARY OPENINGS AND PENETRATIONS THROUGH <br />WALLS, CEILING AND FLOORS. <br />22. ALL EXPOSED PIPES, CONDUITS OR DUCTS IN FINISHES AREAS, WHETHER SHOWN ON <br />DRAWINGS OR NOT, SHALL BE FURRED OUT WITH GYPSUM BOARD. <br />23. LOCATION OF ACCESS DOORS SUPPLIED BY MECHANICAL TRADES AND INSTALLED BY <br />OTHERS SHALL BE DETERMINED IN THE FIELD THROUGH COORDINATION OF TRADES, <br />LOCATION OF LIGHT FIXTURES SHALL GOVERN POSITION OF DUCTS AND PIPES FOR <br />WHICH ACCESS DOORS ARE REQUIRED. ACCESS DOORS SHALL NOT BE PLACED IN <br />INACCESSIBLE POSITIONS OR IN THE WAY OF LIGHTS, GRILLS, REGISTERS, CONCEALED <br />BY CASEWORK, ECT. <br />PROJECT DATA <br />APN: 132-060-10 <br />ZONING: <br />I -L- INDUSTRIAL <br />PROJECT ADDRESS: <br />CHEROKEE RD 0 NEWTON RD (SEC), STOCKTON, CA 95205 <br />PARCEL SIZE- 2.88 ACRES <br />SETBACKS PER I -L ZONING: <br />FRONT YARD: 30' MIN <br />SIDE YARD -STREET SIDE: 20' MIN <br />SIDE YARD -INTERIOR: NONE <br />BUILDING HEIGHT: MAX 45' <br />PERMITTED USE: GASOLINE FILLING STATION, RETAIL FOOD SHOP <br />am/Dm STORE <br />CONSTRUCTION TYPE: V -B <br />USE GROUP: M (CONVENIENCE STORE) <br />ALLOWABLE AREA: 9,000 S.F. <br />ACTUAL GROSS AREA: 3,446 S.F. <br />PER FIRE PREVENTION BUREAU OF SAN JOAQUIN COUNTY: <br />C -STORE LESS THAN 12,000 S.F.- FIRE SPRINKLERS NOT <br />REQUIRED <br />CANOPY <br />CONSTRUCTION TYPE: Il -B <br />USE GROUP: M (FUEL CANOPY) <br />ALLOWABLE AREA: 12,500 S.F. <br />ACTUAL GROSS AREA: 6,050 S.F. <br />PER FIRE PREVENTION BUREAU OF SAN JOAQUIN COUNTY: <br />NON-COMBUSTIBLE FUEL ISLAND- FIRE SPRINKLERS NOT REQUIRED <br />OCCUPANCY AND EGRESS: <br />CONVENIENCE STORE <br />SALES - 1,852 S.F. (1852/60) = <br />31 <br />OFFICE - 380 S.F. (380/100) = <br />4 <br />RESTROOMS - 190 S.F. (EXEMPT) = <br />0 <br />PREP/UTILITY - 405 S.F. (405/200) = <br />3 <br />COOLER/FREEZER - 533 S.F. (533/300) = <br />2 <br />WALL SPACE - 86 S.F. (EXEMPT) = <br />0 <br />TOTAL (NET): 3,170 S.F. = <br />40 OCCUPANTS <br />TOTAL (GROSS): 3,446 S.F. <br />FIRE CODE: <br />EXITS REQUIRED: 1 <br />CALIFORNIA FIRE CODE <br />EXITS PROVIDED: 3 <br />OF CALIF, AND LOCAL JURISDICTION <br />PLUMBING FIXTURE COUNT: <br />CIVIL - EROSION CONTROL NOTES AND DETAILS <br />CONVENIENCE STORE: <br />CIVIL - GRADING PLAN <br />PER CPC TABLE A 422.1 <br />CIVIL - STORM DRAIN PLAN <br />USE GROUP: M (CONVENIENCE STORE) = 200 OCC <br />LOAD <br />ACTUAL GROSS AREA: 3,446 S.F. / 200 = 17.3 <br />USE 18 <br />REQUIRED ALL -GENDER 18 / 2 = 9 <br />CIVIL - NOTES AND DETAILS <br />PER CPC 422.1 <br />CIVIL - NOTES AND DETAILS <br />REQUIRED <br />CIVIL - NOTES AND DETAILS <br />ALL --GENDER FIXTURES REQ = 1 WATER CLOSET, <br />1 IAV <br />PROVIDED <br />ALL -GENDER FIXTURES = 2 WATER CLOSET, 2 LAV <br />APPLICABLE CODES <br />BUILDING CODE : 2016 CALIFORNIA BUILDING CODE <br />SITE VICINITY MAP <br />SITE' <br />PROJECT DIRECTORY <br />OWNER/ APPLICANT <br />ADELFOS PARTNERS <br />13899 DEVRIES ROAD <br />LODI, CA 95242 <br />CONTACT: RICHARD SARRIS <br />(714) 672-0800 <br />ARCHITECT, PETROLEUM <br />BARGHAUSEN CONSULTING ENGINEERS, INC <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: DAN GOALWIN <br />(425) 251-6222 <br />CIVIL ENGINEER <br />BARGHAUSEN CONSULTING ENGINEERS, INC. <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: PETE BAILEY, P.E. <br />(425) 251-6222 <br />LANDSCAPE ARCHITECT <br />BARGHAUSEN CONSULTING ENGINEERS, INC. <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: JEFF VARLEY <br />(425) 251-6222 <br />PLUMBING, MECHANICAL. ELECTRICAL ENGINEER <br />ABOSSEIN ENGINEERING <br />1844 114th AVENUE NORTHEAST <br />BELLEVUE, WA 98004 <br />CONTACT: JAY WERNER <br />(425) 462--9441 <br />GEOTECHNICAL <br />PARAGON GEOTECHNICAL, INC. <br />7979 WENTE WAY <br />SACRAMENTO, CALIFORNIA 95829 <br />(916) 682-0906 <br />SURVEYOR <br />ZIEBATECH LAND SURVEYING <br />9925 WINDSOR WAY <br />SAN RAMON, CA 94583 <br />CONTACT: PIOTR ZIEBA <br />(925) 551-0108 <br />STRUCTURAL- CANOPY <br />FREY-MOSS STRUCTURES <br />100 CELANO CIRCLE <br />PALM DESERT, CA 92211 <br />CONTACT: LEE DRUMMUND <br />(760) 564-9400 <br />DEVELOPMENT CONTACTS <br />BUILDING DEPARTMENT: <br />SAN JOAQUIN COUNTY <br />COMMUNITY DEVELOPMENT DEPT, <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468--3121 <br />HEALTH DEPARTMENT - FOOD: <br />SAN JOAQUIN ENVIRONMENTAL <br />HEALTH DEPARTMENT <br />1868 E HAZELTON AVENUE <br />STOCKTON, CA 95205 <br />(209) 468-3420 <br />CUPA: <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPT <br />1868 EAST HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3420 <br />APCD: <br />SAN JOAQUIN VALLEY <br />AIR POLLUTION CONTROL DISTRICT <br />NORTHERN REGION OFFICE <br />4800 ENTERPRISE WAY <br />MODESTO, CA 95356 <br />(209) 557-6400 <br />FIRE DEPARTMENT: <br />SAN JOAQUIN COUNTY <br />COMMUNITY DEVELOPMENT DEPT <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3121 <br />PUBLIC WORKS: <br />SAN JOAQUIN COUNTY <br />PUBLIC WORKS DEPT. <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3000 <br />WATER: <br />CALIFORNIA WATER SERVICE <br />1505 EAST SONORA ST <br />STOCKTON, CA 95205 <br />547-7900 <br />SEWER: <br />SEPTIC SYSTEM <br />UTILITIES: <br />PACIFIC GAS AND ELECTRIC <br />(PG&E) <br />(800) 743-5000 <br />DEFERRED SUBMITTALS <br />-TRUSS SHOP DRAWINGS <br />-SIGNAGE PERMITS <br />-SOLAR PANEL/ WIRING/ DESIGN PLANS <br />SPECIAL INSPECTIONS <br />-SPECIAL INSPECTIONS: SEE STRUCTURAL SHEET S3.4 FOR REQUIREMENTS <br />INDEX OF DRAWINGS <br />** FOOD FACILITIES SUBMITTAL SHEETS <br />GENERAL <br />T1.1 ** COVER SHEET <br />GC -1 <br />2016 <br />CALGREEN CODE <br />PLUMBING CODE: <br />2016 <br />CALIFORNIA PLUMBING CODE <br />ELECTRICAL CODE: <br />2016 <br />CALIFORNIA ELECTRICAL CODE <br />MECHANICAL CODE: <br />2016 <br />CALIFORNIA MECHANICAL CODE <br />ENERGY CODE: <br />2016 <br />CA ENERGY STANDARDS <br />FIRE CODE: <br />2016 <br />CALIFORNIA FIRE CODE <br />AS AMENDED BY STATE <br />OF CALIF, AND LOCAL JURISDICTION <br />SITE VICINITY MAP <br />SITE' <br />PROJECT DIRECTORY <br />OWNER/ APPLICANT <br />ADELFOS PARTNERS <br />13899 DEVRIES ROAD <br />LODI, CA 95242 <br />CONTACT: RICHARD SARRIS <br />(714) 672-0800 <br />ARCHITECT, PETROLEUM <br />BARGHAUSEN CONSULTING ENGINEERS, INC <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: DAN GOALWIN <br />(425) 251-6222 <br />CIVIL ENGINEER <br />BARGHAUSEN CONSULTING ENGINEERS, INC. <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: PETE BAILEY, P.E. <br />(425) 251-6222 <br />LANDSCAPE ARCHITECT <br />BARGHAUSEN CONSULTING ENGINEERS, INC. <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />CONTACT: JEFF VARLEY <br />(425) 251-6222 <br />PLUMBING, MECHANICAL. ELECTRICAL ENGINEER <br />ABOSSEIN ENGINEERING <br />1844 114th AVENUE NORTHEAST <br />BELLEVUE, WA 98004 <br />CONTACT: JAY WERNER <br />(425) 462--9441 <br />GEOTECHNICAL <br />PARAGON GEOTECHNICAL, INC. <br />7979 WENTE WAY <br />SACRAMENTO, CALIFORNIA 95829 <br />(916) 682-0906 <br />SURVEYOR <br />ZIEBATECH LAND SURVEYING <br />9925 WINDSOR WAY <br />SAN RAMON, CA 94583 <br />CONTACT: PIOTR ZIEBA <br />(925) 551-0108 <br />STRUCTURAL- CANOPY <br />FREY-MOSS STRUCTURES <br />100 CELANO CIRCLE <br />PALM DESERT, CA 92211 <br />CONTACT: LEE DRUMMUND <br />(760) 564-9400 <br />DEVELOPMENT CONTACTS <br />BUILDING DEPARTMENT: <br />SAN JOAQUIN COUNTY <br />COMMUNITY DEVELOPMENT DEPT, <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468--3121 <br />HEALTH DEPARTMENT - FOOD: <br />SAN JOAQUIN ENVIRONMENTAL <br />HEALTH DEPARTMENT <br />1868 E HAZELTON AVENUE <br />STOCKTON, CA 95205 <br />(209) 468-3420 <br />CUPA: <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPT <br />1868 EAST HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3420 <br />APCD: <br />SAN JOAQUIN VALLEY <br />AIR POLLUTION CONTROL DISTRICT <br />NORTHERN REGION OFFICE <br />4800 ENTERPRISE WAY <br />MODESTO, CA 95356 <br />(209) 557-6400 <br />FIRE DEPARTMENT: <br />SAN JOAQUIN COUNTY <br />COMMUNITY DEVELOPMENT DEPT <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3121 <br />PUBLIC WORKS: <br />SAN JOAQUIN COUNTY <br />PUBLIC WORKS DEPT. <br />1810 E. HAZELTON AVE <br />STOCKTON, CA 95205 <br />(209) 468-3000 <br />WATER: <br />CALIFORNIA WATER SERVICE <br />1505 EAST SONORA ST <br />STOCKTON, CA 95205 <br />547-7900 <br />SEWER: <br />SEPTIC SYSTEM <br />UTILITIES: <br />PACIFIC GAS AND ELECTRIC <br />(PG&E) <br />(800) 743-5000 <br />DEFERRED SUBMITTALS <br />-TRUSS SHOP DRAWINGS <br />-SIGNAGE PERMITS <br />-SOLAR PANEL/ WIRING/ DESIGN PLANS <br />SPECIAL INSPECTIONS <br />-SPECIAL INSPECTIONS: SEE STRUCTURAL SHEET S3.4 FOR REQUIREMENTS <br />INDEX OF DRAWINGS <br />** FOOD FACILITIES SUBMITTAL SHEETS <br />GENERAL <br />T1.1 ** COVER SHEET <br />GC -1 <br />GREEN BUILDING CHECKLIST <br />GC -2 <br />GREEN BUILDING CHECKLIST <br />GC -3 <br />GREEN BUILDING CHECKLIST <br />SURVEY <br />ROOF FRAMING PLAN <br />1 of 1 <br />TOPOGRAPHIC AND BOUNDARY SURVEY <br />CIVIL <br />DETAILS <br />C1.0 <br />CIVIL - COVER SHEET <br />C2.0 <br />CIVIL - SITE PLAN <br />C2.1 <br />CIVIL - HORIZONTAL CONTROL PLAN <br />C3.0 <br />CIVIL - DEMOLITION AND EROSION CONTROL PLAN <br />C3.1 <br />CIVIL - EROSION CONTROL NOTES AND DETAILS <br />C4.0 <br />CIVIL - GRADING PLAN <br />C4.1 <br />CIVIL - STORM DRAIN PLAN <br />C5.0** <br />CIVIL -- UTILITY PLAN <br />C5.1 <br />CIVIL - WATER NOTES <br />C6.0 <br />CIVIL - NOTES AND DETAILS <br />C6.1 <br />CIVIL - NOTES AND DETAILS <br />C6.2 <br />CIVIL - NOTES AND DETAILS <br />C7.0 <br />CIVIL - ARCO SITE SPECIFICATIONS <br />C7.1 <br />CIVIL - ARCO SITE SPECIFICATIONS <br />C7.2 <br />CIVIL - ARCO SITE SPECIFICATIONS <br />LANDSCAPE <br />FAULT CURRENT CALCULATIONS <br />L1 <br />LANDSCAPE PLAN <br />L2 <br />LANDSCAPE NOTES & DETAILS <br />L3 <br />IRRIGATION PLAN <br />L4 <br />IRRIGATION NOTES & DETAILS <br />ARCHITECTURAL <br />A1.1 ** <br />am/pm CONSTRUCTION FLOOR PLAN <br />A1.1 a <br />OVERALL BUILDING EXITING PLAN <br />A1.1 b <br />OVERALL BUILDING ACCESSIBILITY PLAN <br />A1.2 ** <br />FLOOR FINISH PLAN <br />A1.3 ** <br />REFLECTED CEILING PLAN <br />A1.3a ** <br />SOFFIT PLAN <br />A1.4 <br />ROOF PLAN <br />A2.1 <br />EXTERIOR ELEVATIONS <br />A2.3 ** <br />INTERIOR ELEVATIONS <br />A2.4 ** <br />INTERIOR ELEVATIONS <br />A2.5 ** <br />INTERIOR ELEVATIONS <br />A2.6 ** <br />INTERIOR ELEVATIONS AND ENLARGED RESTROOM PLAN <br />A2.7 <br />GRAPHIC ELEVATIONS <br />A3.1 <br />BUILDING SECTIONS <br />A3.2 <br />WALL SECTIONS <br />A3.3 <br />WALL SECTIONS <br />A4.1 ** <br />DETAILS <br />A4.2 ** <br />DETAILS <br />A4.3 ** <br />DETAILS <br />A5.1 <br />DOOR AND WINDOW SCHEDULE <br />A7.1 <br />ARCHITECTURAL SPECIFICATIONS <br />A7.2 <br />ARCHITECTURAL SPECIFICATIONS <br />A7.3 <br />ARCHITECTURAL SPECIFICATIONS <br />A7.4 <br />ARCHITECTURAL SPECIFICATIONS <br />A7.5 <br />ARCHITECTURAL SPECIFICATIONS <br />A7.6 <br />ARCHITECTURAL SPECIFICATIONS <br />Q1.1 ** EQUIPMENT PLAN <br />Q1.2 ** COOLER PACKAGE <br />Q2.1 ** EQUIPMENT SCHEDULE <br />Q2.3 ** SMALL WARES SCHEDULE <br />TE.1 ** TRASH / RECYCLE ENCLOSURE PLANS <br />TE.2 ** TRASH / RECYCLE ENCLOSURE PLANS <br />STRUCTURAL - C -STORE <br />SOA <br />LOT LIGHT STRUCTURAL NOTES AND DETAIL <br />S1,1 <br />FOUNDATION PLAN <br />S1.2 <br />CEILING FRAMING PLAN <br />S1.3 <br />ROOF FRAMING PLAN <br />S21 <br />DETAILS <br />S2.2 <br />DETAILS <br />S2.3 <br />DETAILS <br />S2.4 <br />DETAILS <br />S2.5 <br />DETAILS <br />S2.6 <br />DETAILS <br />S2.7 <br />DETAILS <br />S2.8 <br />DETAILS <br />S2.9 <br />DETAILS <br />S2.10 <br />ELEVATIONS <br />S3.1 <br />GENERAL NOTES <br />S3.2 <br />GENERAL NOTES <br />S3,3 <br />GENERAL NOTES <br />S3,4 <br />GENERAL NOTES <br />7.1�I�7,'�1:Zil:[IfC�llli1J:711 <br />CA.1 <br />CANOPY SLAB PLAN <br />CA.2 <br />CANOPY ELEVATIONS <br />CA.3 <br />CANOPY REFLECTED CEILING PLAN <br />CANOPY- <br />STRUCTURAL <br />CS1 <br />COVER SHEET <br />E1 <br />FRAMING PLAN <br />E2 <br />ELEVATIONS <br />E3 <br />LIGHTING AND SOFFIT PLAN <br />E4 <br />SECTION <br />E5 <br />SECTION <br />F1 <br />FOUNDATION PLAN <br />PLUMBING <br />PLAN <br />PO.1 ** <br />PLUMBING LEGEND, NOTES, SCHEDULES <br />P0.2 ** <br />PLUMBING NOTES & SCHEDULES <br />P2.0 ** <br />SANITARY DRAINAGE & VENT PLUMBING PLAN <br />P3.0 ** <br />WATER PLUMBING PLANT <br />P4.0 <br />PLUMBING ROOF PLAN <br />P5.0 ** <br />SANITARY <br />& WATER RISER <br />P&O ** <br />PLUMBING <br />DETAILS <br />P6.1 ** <br />PLUMBING <br />DETAILS <br />P6.2 ** <br />PLUMBING <br />DETAILS <br />INDEX OF DRAWINGS -CONT <br />MECHANICAL <br />MO.1 ** EQUIPMENT SCHEDULE, LEGEND, NOTES <br />MO.2 ** MECHANICAL SPECIFICATIONS <br />MO.3 <br />MECHANICAL <br />T-24 <br />FORMS <br />MO.4 <br />MECHANICAL <br />T-24 <br />FORMS <br />MO.5 <br />MECHANICAL <br />T-24 <br />FORMS <br />MO.6 <br />MECHANICAL <br />T-24 <br />FORMS <br />MO.7 <br />MECHANICAL <br />T-24 <br />FORMS <br />M2.1 ** <br />MECHANICAL <br />FLOOR <br />PLAN <br />M2.2 <br />MECHANICAL <br />ROOF <br />PLAN <br />M6.1 ** <br />MECHANICAL <br />DETAILS <br />M6.2 ** <br />HOOD & FAN SHOP DRAWINGS <br />M9.1 ** <br />CONTROLS <br />ELECTRICAL ROOF PLAN <br />E4.0 <br />ELECTRICAL <br />EO.1 <br />LEGEND, NOTES & SCHEDULES <br />EO.2 <br />SPECIFICATIONS <br />E0.3.1 <br />SINGLE LINE DIAGRAM <br />EO.3.2 <br />ELECTRICAL PANEL SCHEDULES <br />EO.4 <br />TITLE 24 FORMS -INDOOR LIGHTING PART 1 <br />EO.5 <br />TITLE 24 FORMS -INDOOR LIGHTING PART 2 <br />EO.6 <br />TITLE 24 FORMS -OUTDOOR LIGHTING PART 1 <br />EO.7 <br />TITLE 24 FORMS -OUTDOOR LIGHTING PART 2 <br />EO.8 <br />TITLE 24 FORMS -SOLAR FORMS <br />EO.9 <br />TITLE 24 FORMS -SOLAR FORMS <br />ED.10 <br />TITLE 24 FORMS -SIGN FORMS <br />EO.11 <br />TITLE 24 FORMS -POWER FORMS <br />E1.0 <br />LIGHTING PLAN <br />E2.0 <br />POWER PLAN <br />E2.1 <br />ELECTRICAL ROUGH -IN PLAN <br />E2.2 <br />ELECTRICAL & RECEPTACLE SCHEDULES <br />E2.3 <br />POWER & LIGHTING SITE PLAN <br />E3.0 <br />ELECTRICAL ROOF PLAN <br />E4.0 <br />COMMUNICATION PLAN <br />E5.0 <br />DIAGRAMS & DETAILS PART 1 <br />E5.1 <br />DIAGRAMS & DETAILS PART 2 <br />E5.2 <br />FAULT CURRENT CALCULATIONS <br />PETROLEUM PLANS <br />G.O.O TITLE SHEET AND DRAWING INDEX <br />G.O.2.0 UNDERGROUND TANK AND PIPING SITE PLAN AND INSTALLATION NOTES <br />G.0.2.1 TANK & PIPING SCOPE OF WORK & GENERAL NOTES (FRP 1 OF 2) <br />G.0.2.2 TANK & PIPING SCOPE OF WORK & GENERAL NOTES (FRP 2 OF 2) <br />G.0.5 DESIGN INTENT MISCELLANEOUS DETAILS AND VACUUM MONITORING <br />DIAGRAM <br />G.0.6.5 DESIGN INTENT: NEW VENT STACK INSTALLATION DETAILS W/ <br />HORIZONTAL FFA/HEALY CLEAN AIR SEPARATOR <br />G.0.7.2 TANK FILL & VAPOR RISER STATIC GROUNDING DETAILS <br />(CALIFORNIA ONLY) <br />M.5.3.01 TANK AND PIPING MATERIALS LIST (1 OF 2) <br />M.5.3.02 TANK AND PIPING MATERIALS LIST (2 OF 2) <br />M.5.3.03 TYPICAL 25,000 GALLON DOUBLE WALL FIBERGLASS TANK INSTALLATION <br />DETAILS <br />M.5.3.05 TYPICAL 12,000/10,000 GALLON DOUBLE WALL FIBERGLASS TANK <br />INSTALLATION DETAILS <br />M.5.3.08 UST INSTALLATION (1) 10'0 25K & (1) 10'0 12K/10K BLENDING, DOUBLE <br />WALL VENT & VAPOR W/DIESEL <br />M.5.3.12 TURBINE SIDE SUMPS AND PIPING INSTALLATION DETAILS <br />M.5.3A6 FILL SIDE SUMP INSTALLATION DETAILS (DOUBLE WALL VENT/VAPOR) <br />M.5.3.18 DIESEL FILL SIDE SUMP INSTALLATION DETAILS (DOUBLE WALL VENT) <br />M.5.3,23 DISPENSER DETAILS: WAYNE OVATION (3+0) BLEND DISPENSER <br />INSTALLATION DETAILS (D.W. VAPOR) <br />M.5.3.25 DISPENSER DETAILS: WAYNE OVATION (3+1) BLEND DISPENSER <br />INSTALLATION DETAILS (D.W. VAPOR) <br />M.5.3.26 TANK SLAB CONCRETE SPECIFICATIONS & IDENTIFICATION <br />MARKING DETAILS <br />M.5.3.27 ELECTRICAL FUELING SITE PLAN <br />M.5.3.28 ELECTRICAL FUELING POINT-TO-POINT CONDUIT PLAN <br />M.5.3.29 IST-VFC, CAT 5, AND VEEDER-ROOT NOTES <br />M.5.3.30 ELECTRICAL FUELING DETAILS FOR VEEDER-ROOT & POWER <br />DISTRIBUTION CENTER (25K 12K/10K TANKS) <br />M.5.3.31 ELECTRICAL PANEL POWER AND CONTROL WIRING DETAILS <br />M.5.3.32 ELECTRICAL PANEL E -STOP CONTROL WIRING SCHEMATIC AND TYPICAL <br />FUELING ELEVATION <br />M.5.3.33 ELECTRICAL PANEL E -STOP DATA/INTERCOM/MEDIA WIRING DIAGRAMS <br />M.5.3.34 EMERGENCY SHUTDOWN SCHEMATIC FUELING CONTROL W/VFC's <br />M.5.3.35 EMERGENCY SHUTDOWN DETAILS FUELING CONTROL W/VFC's <br />SAN JOAQUkN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 E. HAZELTON AVE. <br />STOCKTON, CA 95205 <br />(209) 488-3420 <br />❑ Approved <br />' Approved with changes: See Remarks <br />❑ Disapprov d Seeemark 4 <br />Remarks _a '[�-- <br />Date By <br />Approvalxte ds only to that which is shown and described <br />hereon and does not aulhorize or approve any omission or <br />deviation from requirements of state laws or local ordinances. <br />CLIENT: <br />bp <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />OV4AU`A <br />V' <br />40 <br />d <br />�w <br />NC <br />ENGIN <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />(425)251-6222 <br />(425)251-8782 FAX <br />CIVIL ENGINEERING, LAND PLANNING, <br />SURVEYING, ENVIRONMENTAL SERVICES <br />NO. <br />DATE <br />REVISION DESCRIPTION <br />- <br />02/22/18 <br />PERMIT SUBMITTAL <br />t <br />2 <br />3 <br />0 <br />A <br />0 <br />to <br />11 <br />SEAL: <br />OE CALIFO <br />DANIEL BRIAN � <br />GOALWIN <br />REN.8-31-2019 <br />yse'0 ARG\ <br />DEVELOPMENT INFORMATION: <br />ARCO NTI <br />AM/PM <br />FUEL CANOPY w/ 8 MPD's <br />SITE ADDRESS: <br />NWC CHEROKEE RD <br />@ NEWTON RD <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />FACILITY #TBD <br />DESIGNED BY: <br />ALLIANCE Z&OM: <br />OIEO(ED BY: <br />BP REPM: <br />DRA94N BY: <br />ALLIANCE PAI: <br />VERSION: _ <br />PROTECT NO: <br />18068 <br />DRAWING TITLE: <br />COVER SHEET <br />SHEET NO: <br />T191 <br />