Laserfiche WebLink
PERCOLATION TEST REPORT <br /> FOR <br /> Walter Coleman Property <br /> PAh.CEI MAP NO. MS-90-6U <br /> prepared by <br /> Dwain C. Tosch <br /> Civil Engineer <br /> CE #14644 <br /> 1229 Goldenoak Wray <br /> Stockton, California, 95209 <br /> Phone: (209) 478-4606 <br /> PROJECT DESCRIPTION: To separate out Parcel 1, containing <br /> 2.50 acres from a 4.82 acre parcel <br /> resulting in the remaining, being <br /> 2.32 acres. <br /> TEST RESULTS: Two shallow, hole percolation tests <br /> were started but were discontinued <br /> because of obvious failures. <br /> Two deep hole percolation tests were <br /> run because of the failures of the <br /> shallow hole percolation tests. <br /> • Parcel 1 deep Test hole Percolation <br /> Rate = 24 minutes per inch. <br /> o -%-r4 -. d rrsp.v� aie� <br /> • Remainder parcel deep Test Hole <br /> Percolation Rate = 2U minutes per <br /> inch 9, 00O S�44 w/ -, ',�S <br /> -Svrlle 4 rQS <br /> REGOIIPIENDATION: Combination of leach lines and pits <br /> is recommended. <br />