Laserfiche WebLink
ranging from 38.5 to 46.5 feet BGS. Soil samples were collected at each location, and grab <br /> groundwater samples were collected from SB-1 and SB-2. The samples were analyzed for <br /> TPH-g and BTEX. The maximum detected concentration of TPH-g in soil was 13,000 mg/kg <br /> in the sample from VE-1 at 21 feet BGS. TPH-g was detected at 180,000 micrograms-per-liter <br /> (µg/L) in the grab groundwater sample collected from SBA and 190,000 µg/L in the sample <br /> collected from SB-2. <br /> MW-1 was completed as a 2-inch diameter groundwater monitoring well screened from 20 to <br /> 46 feet BGS. VE-1 was completed as a 4-inch diameter vapor monitoring well screened from <br /> 15 to 35 feet BGS. Monitoring well MW-1 was developed and sampled on February 6, 1997. <br /> TPH-g was detected in the groundwater sample at a concentration of 160,000 µg/L. The BTEX <br /> constituents were detected at concentrations of 22,000 gg/L, 36,000 µg/L, 4,100 gg/L and <br /> 20,000 gg/L, respectively(Secor, 1996). <br /> October 1997 Well Installation <br /> In October 1997, Secor drilled one soil boring (MW-7) through the former tank excavation to a <br /> total depth of 90 feet BGS. Soil samples were collected between 34.5 and 79 feet BGS and <br /> grab groundwater samples were collected at approximately 35 and 41 feet BGS. The maximum <br /> detected concentration of TPH-g was 390 mg/kg in soil at 34.5 feet BGS and 400,000 gg/L in <br /> groundwater at 41 feet BGS. MW-7 was completed as a nested groundwater monitoring well <br /> with MW-7S constructed using 2-inch diameter casing and screened from 55 to 63 feet BGS, <br /> and MW-7D constructed with 2-inch diameter casing and screened from 80 to 85 feet BGS. <br /> Following development, MW-7S and MW-7D were sampled on October 31, 1997 and analyzed <br /> for TPH-g, BTEX, and five fuel oxygenates (methyl tertiary butyl ether (MTBE), di-isopropyl <br /> ether (DIPE), ethyl tertiary butyl ether (ETBE), tertiary amyl methyl ether (TAME) and tertiary <br /> butyl alcohol [TBA]). TPH-g was detected at concentrations of 100,000 gg/L and 10,000 µg/L <br /> in groundwater samples collected from MW-7S and MW-7D, respectively. Benzene was <br /> detected in groundwater samples collected from MW-7S and MW-7D at concentrations of <br /> 19,000 µg/L and 1,300 gg/L, respectively. MTBE was detected in the sample collected from <br /> MW-7S at a concentration of 120 gg/L(Secor 1997). <br /> December 1997 Cone Penetrometer Testing Investigation <br /> In December 1997, Secor drilled three cone penetration test (CPT) borings (CPT-1 through <br /> CPT-3). CPT-1, CPT-2 and CPT-3 were drilled to depths of 125, 115, and 120 feet BGS, <br /> respectively. One soil sample was collected from CPT-1 at 125 feet BGS, and grab <br /> groundwater samples were collected at various depths from each boring. TPH-g was not <br /> detected in the soil sample. The maximum detected concentration of TPH-g in groundwater <br /> was 17,000 gg/L in CPT-2 at 82 feet BGS (Secor, 1998). <br /> 5 <br />