My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LONGE
>
7910
>
2231-2238 – Tiered Permitting Program
>
PR0536175
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 9:43:30 AM
Creation date
3/3/2020 11:41:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0536175
PE
2231
FACILITY_ID
FA0012466
FACILITY_NAME
PREMIER FINISHING
STREET_NUMBER
7910
Direction
S
STREET_NAME
LONGE
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
7910 S LONGE
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
350
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
hardness of the water in the rinse tanks are tested daily with a HM COM 100 digital meter. When <br /> the water hardness in the rinse tanks reaches a concentration of 500 mg/l, the rinse waters are then <br /> pumped into the treatment tank (each rinse tank is pumped into the treatment tank approximately <br /> twice per month). The pH is tested prior to pumping water from any of the rinse tanks into the <br /> treatment tank, if the pH in any of the rinse tanks is 2, or less, the rinse water will not be pumped <br /> into the treatment tank, but would be pumped directly into drums or totes and managed as a <br /> corrosive characteristic hazardous waste. <br /> The process tanks are typically never emptied, but rather replenished with de-ionized water and <br /> iron phosphate (CC 50L). If for any reason the process tanks would have to be emptied, the tanks <br /> would be tested for pH. If the pH of the process tanks is greater than 2, the wastewater would then <br /> be pumped to the treatment tank in the salve manner as the rinse tanks. If the pH of the wastewater <br /> in the process tanks is 2, or less, it would then be pumped directly into deans or totes and managed <br /> as a corrosive characteristic hazardous waste. <br /> 1.3 Chem Line <br /> The chem line consists of 16 tanks and a sump [Attachment E — Chem Line Diagram]. Tanks <br /> A,41, #3, #5, #12, and#14 on the chem line are process tanks and tanks B, #2, #4, #6, #8,49, 911 <br /> and 413 are rinse tanks, currently tank #7 is empty and not in use. Tank A contains de-ionized <br /> water and New Dimension Supreme, tank#1 contains de-ionized water and Iridite ZDC Activator, <br /> tank#3 contains de-ionized water and Alumatte Etch,tank 45 contains de-ionized water and DeOx <br /> 710 Non-Chromated Deoxidizer, tank #12 contains de-ionized water and Iridite NCP, and tank <br /> #14 contains de-ionized water and Chemeon TCP-HF. As needed the process tanks (Tanks A, #1, <br /> #3, #5, #12, and #14) get small amounts of defoamer 15 to keep the foam from accumulating. <br /> [Attachment F — Iridite ZDC Activator, Alumatte Etch, DcOx 710 Non-Chromated <br /> Deoxidizer,Iridite NCP, Chemeon TCP-HF, and Defoamer 15 Safety Data Sheets]. The rinse <br /> tanks only contain de-ionized water(no chemicals are added to the rinse tanks) and these tanks are <br /> only used to rinse metal products after they have been immersed in the process tanks to remove <br /> corrosive etches. Weekly,Monday—Thursday the rinse tanks are pumped directly to the treatment <br /> tank. The rinse tanks are emptied on the following schedule: <br /> - Monday: tanks #9 & #11 <br /> - Tuesday: tanks B, #2 & 46 <br /> - Wednesday: tanks #4, #9 & #13 <br /> - Thursday: tanks B, #2, #6 & 411 <br /> The pH is tested prior to puanping water from any of the rinse tanks into the treatment tank, if the <br /> pH in any of the rinse tanks is 2, or less or 12.5, or more, the rinse water will not be pumped into <br /> Premier Finishing YYaste Analysis Plmi <br /> 2 <br />