MIL-D-16627(BuOrd) <br /> 4.3.3.3 Procedure.- Insert the solution of the standard dye <br /> prepared in accordance with 4.3.3.1 in the colorimeter and, <br /> using the specified filter, set the percentage transmission <br /> at 50. Then insert the solution of the sample dye and determine <br /> the percentage transmission. Read the percentage concentration <br /> directly from the percentage transmission on the applicable <br /> graph for the particular color dye being tested ( see figure <br /> 1 ) . If the percentage concentration is greater than 100, <br /> then the sample is stronger than the standard. <br /> 4.3.4 Moisture.- Transfer a weighed portion of approximately <br /> 2 grams of the sample to a tared moisture dish and dry in a <br /> sulfuric acid desiccator for 72 hours . The glass dish shall <br /> be such that it can be covered during the weighings, because <br /> of the rapid moisture absorption of the dye. From the loss <br /> in weight , calculate the percentage moisture in the sample. <br /> 4.3.5 Fineness.- Place an accurately weighed portion of <br /> approximately 10 grams of the sample on a No. 325 U. S. <br /> Standard sieve assembled with a bottom pan. Brush vigorously, <br /> but not hard enough to injure the sieve, for 10 minutes with <br /> a fairly stiff, round, paint brush. Remove the sieve from <br /> the bottom pan, place it on a piece of clean white paper <br /> and brush again for 3 minutes. Add any material that passes <br /> the screen to the material in the pan. Continue the 3-minute <br /> brushing periods until less than 1 percent of the residue <br /> passes through the screen. Weigh the material retained on <br /> the sieve and calculate the percentage of material passing <br /> through the sieve. <br /> 4.3.6 Color stability.- Transfer 2 ml of the dye solution <br /> which was prepared for the concentration test (4.3.3.1) to a <br /> colorless glass test tube and dilute to 30 ml. Hold the solu- <br /> tion up to the light and examine for color change. <br /> 5. PREPARATION FOR DELIVERY <br /> 5.1 Packing.- Unless otherwise specified, projectile-spotting <br /> dye shall be delivered in standard 50-pound airtight metal drums <br /> so constructed as to insure acceptance by common or other <br /> carriers, for safe transportation, at the lowest rate, to the <br /> point of delivery. <br /> 5.2 Marking.- In addition to any special marking required by <br /> the contract or order, drums shall be marked in accordance with <br /> j the Navy Shipment Marking Handbook. <br /> E <br /> 4 <br /> E <br />