My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO 1983-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
U
>
UNION
>
1085
>
2900 - Site Mitigation Program
>
PR0545446
>
COMPLIANCE INFO_COMPLIANCE INFO 1983-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2020 12:47:13 PM
Creation date
3/3/2020 12:21:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO 1983-2007
RECORD_ID
PR0545446
PE
2961
FACILITY_ID
FA0019341
FACILITY_NAME
GORDON PROPERTY
STREET_NUMBER
1085
Direction
S
STREET_NAME
UNION
STREET_TYPE
RD
City
MANTECA
Zip
95337
CURRENT_STATUS
02
SITE_LOCATION
1085 S UNION RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MII,C-11796B <br /> 68 grams of sodium dichromate, ACS. natant liquid. Remove a small amount of the <br /> 15 ml. of sulfuric acid, ACS. sedimented material with a pipette, or with <br /> The discs shall then be rinsed with dis- a long medicine dropper. Place a few drops <br /> tilled water and dried for 1/2 hour in an oven of the material on a new clean microscope <br /> maintained at 221° to 230° F. glass slide, and allow the solvent to evapo- <br /> rate at room temperature. After evaporation <br /> 4.6.4.2 Procedure. A brass catalyst disc rub a similar slide against the side of the <br /> shall be placed at the bottom of each glass slide containing the dried Lresidue, and ex- <br /> dish and covered with 4.0±0.01 grams of the amine both slides for scratches. Any scratch- <br /> compound. The remainder of the determina- ing of the glass slides shall be attributable <br /> tion shall be carried out in accordance with to the presence of abrasives in the compound. <br /> Method 3453 of Federal Standard No. 791. 4:6.7 Slick (Class 1A only). Coat the <br /> blades of a laboratory stirrer with the com- <br /> pound by immersing ,the shaft for 1 minute <br /> (Class 3 only). A mixture composed of 5 to a depth of 1 inch in the compound held at <br /> parts by weight of the compound, and 95 a temperature of 190° F. Allow to dxain <br /> parts of lubricating oil conforming to grade and cool to 75±5° F. Place a beaker con- <br /> 1100 of Specification MIL-L-6082, shall be twining 200 ml. of 4-percent sodium chloride <br /> placed in a 35-by-200 mm. test tube. The solution at 100° F., so that the blades of the <br /> tube and its contents shall be heated for one stirrer are submerged 1 inch beneath the <br /> hour in an oil bath maintained at 170° ±2° surface of the solution. Allow the shaft to <br /> F. The tube shall then be removed, stoppered rotate for 3 minutes at approximately 1,500 <br /> with a cork while still hot, and agitated rpm. Set the beaker on black paper in front <br /> vigorously for 1/2 minute. The tube shall be of a window. View the surface of the salt <br /> returned to the oil bath and reheated for 1 solution at an angle of approximately 450, <br /> hour. The mixture shall be examined forr <br /> to determine whether or not an oily film <br /> miscibility while still hot, and again after (slick) has been formed. <br /> cooling to 75°±5°F. After being exposed oto <br /> room temperature for 20 hours, the mixture 4.6.8.1 Humidity Cabinet. This test shall <br /> shall again be examined for separation of be conducted in accordance with Method 5310 <br /> the compound and the oil. of Federal Standard No. 791 with the follow- <br /> ing changes: <br /> 4.6.6 Abrasives. Dissolve 5 grams of the 4.6.8 Corrosion protection. <br /> compound in a small portion of methyl <br /> chloroform, and pour the dissolved sample 4.6.8.1.1 Coating test panels. Three test <br /> into a cone-shaped centrifuge tube. Add panels shall be immersed in the molten com- <br /> Methyl chloroform to make a total volume of pound, maintained at an experimentally de- <br /> 100 milliliters. The apparatus and procedure termined temperature below the maximum <br /> described in paragraphs 3 and 5 of method temperature of application permissible for <br /> 3101 of Federal Standard No. 791 shall be the class of compound under test (see <br /> used in making the sedimentation of,the ma- 3.10.1), until the temperature of the panels <br /> terial for the abrasive determination. How- reaches that of the compound. The panels <br /> ever, only one test §hall be made on each shall then be mechanically withdrawn at the <br /> sample of the compound, instead of the dup- rate of 4 inches per minute so that a film of <br /> licate test stipulated by the specified method. compound, 1.5±0.2 mils in thickness, shall <br /> The total volume of the centrifuged sediment adhere to the panels. <br /> shall not exceed 0.05 milliliters. 4.6.8.1.2 Filen thickness. The thickness of <br /> Decant all but a few milliliters of the super- the applied film shall be determined usin(r <br /> 6 <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.