Laserfiche WebLink
MIL—C-11796B <br /> panels that are similar in surface finish (see the panels shall show more than three cor- <br /> 4.6.8.1). A specific gravity-weight method, rosion dots, none of which exceeds 1 milli- <br /> or any other suitable method, may be used meter in diameter. Corrosion in excess of <br /> for making the determination. When a spe- this amount shall be cause for rejection. <br /> cific gravity-weight method is used the test <br /> specimen shall be of a design that will pre- 4.6.8.3 Shed storage. Three test panels <br /> clude gross errors due to accumulation of shall be cleaned and polished (see 4.6.8.1), <br /> material at the bottom of the specimen. For and coated (see 4.6.8.1.1) with a film of <br /> a specific gravity-weight method the film 1.5 ± 0.2 mils. After standing for approxi- <br /> thickness may be calculated as follows: mately 16 hours the panels shall be stored in <br /> l000 X w X 0.061 <br /> a shed of the type illustrated in figures 1 and Film thickness (in mils) 2. The shed shall be exposed to the weather <br /> where, D X A in an unshaded location in the vicinity of <br /> 1 mil — 0.001 inch Rock Island Arsenal, Rock Island, Ill. At the <br /> 0.061 cu. in. s 1 cubic centimeter <br /> W — weight of film, grams end of a one year storage period, the remov- <br /> D — density of the film, grams/cc ability test (see 4.6.11) shall be conducted. <br /> A total surface area of the spec- The panels shall then be examined in the <br /> imen, square inches significant area as defined in Specification <br /> JAN—H-792. At least two of the panels shall <br /> 4.6.8.1.3 Test procedure. The panels shall be free of corrosion and the third panel shall <br /> be permitted to stand for approximately 16 have no more than three corrosion dots, none <br /> hours after dipping and then suspended by of which exceeds 1 millimeter in diameter. <br /> stainless steel or monel hooks and subjected Corrosion in excess of this amount shall be <br /> to 30 days of the humidity cabinet test de- cause for rejection. <br /> scribed in Method 5310 of Federal Standard <br /> No. 791. At the end of the 30 day test the 4.6.8.4 Outdoor storage. Three test panels <br /> panels shall be removed, decoated with shall be cleaned and polished (see 4.6.8.1), <br /> naphtha, and examined in the significant and coated with a film of 50 to 55 mils. In <br /> area of the panels as defined in Specification order to obtain a film of 50-55 mils the com- <br /> JAN—H-792. At least two of the panels shall pound should be heated to a temperature <br /> be free of corrosion and the third panel shall slightly above the melting point. The panels <br /> have no more than three corrosion dots, none are immersed and mechanically withdrawn <br /> of which exceeds 1 millimeter in diameter. at a rate sufficient to provide the desired <br /> Corrosion in excess of this amount shall be thickness. After standing for approximately <br /> cause for rejection. 16 hours the panels shall be openly exposed <br /> to the weather for one year in an unshaded <br /> 4.6.8.2 Accelerated weathering. Three test location in the vicinity of Rock Island Ar- <br /> panels shall be cleaned and polished (see senal, Rock Island, 111. The panels shall be <br /> 4.6.8.1), and coated (see 4.6.8.1.1) with a inclined 45° from the vertical, with the <br /> film of 1.5±0.2 mils. After standing for ap- coated test surface facing due south. At the <br /> proximately 16 hours the panels shall be ex- end of the one year exposure period, the <br /> posed for 300 operating hours in the acceler- removability test (see 4.6.11) shall be con- <br /> ated weathering apparatus specified in ducted. The panels shall then be examined <br /> Method 6151 of Federal Test Method Stand- in the significant area as defined in Specifi- <br /> ard No. 141. At the end of the 300 hour cation JAN—H-792. None of the panels shall <br /> exposure period, the removability test (see show more than three corrosion dots, none. <br /> 4.6.11) shall be conducted. The panels shall of which exceeds 1 millimeter in diameter. <br /> then be examined in the significant area as Corrosion in excess of this amount shall be <br /> defined in Specification JAN-11-792.None of cause for rejection. <br /> 7 <br /> i <br />