Laserfiche WebLink
Tracy Cold Storage <br /> Addendum to Case Closure Request <br /> Page: 2 <br /> • No additional construction data is available for the South Well. A video log of the <br /> South Well will not provide information regarding the placement or condition of the <br /> well seal.. Ground water analytical data collected over the past few years,-which <br /> indicate no detectable contaminants in the lower aquifers, provide the best evidence <br /> that the well seal for the South Well is intact and functioning properly. <br /> • During more than 40 years of facility operation substantial,volumes of water have <br /> been extracted with no demonstrated impact to ground water quality. The South Well <br /> served as the primary water well during this period. This includes the period of time <br /> that the maximum threat to ground water quality existed following the UST leak in <br /> the 1970's. Over the past five years multiple water samples have been collected from <br /> each well, both before and after the remedial excavation, with no detectable levels of <br /> gasoline or gasoline constituents detected in either the North Well or South Well. <br /> Table 1 below summarizes the analytical data for the two wells. The analytical data <br /> covers the period of time that the South Well was providing the bulk of the plant's <br /> water needs and coincides with the period of time which would have presented the <br /> greatest risk to ground water quality. <br /> TABLE 1 <br /> Summary of Ground Water Analytical Results, <br /> Water Supply Wells <br /> Analyte <br /> Sample Sample Benzene Toluene Ethyl Total TPH-Gas <br /> Location Date Benzene Xylenes <br /> (Fig/L) (ltg/L) (µg/L) (FLg/L) tmg/L) <br /> 12/21/95 ND ND ND ND ND <br /> North Well 09/30/98 ND ND ND ND ND <br /> 12/18/98 ND ND ND ND ND <br /> 06/22/99 ND ND ND ND ND <br /> 12/21/95 ND ND ND ND ND <br /> South Well 09/30/98 ND ND ND ND ND <br /> 12/18/98 ND ND ND ND ND <br /> 06/22/99 ND ND ND ND ND <br /> ND=Not detected above the laboratory detection limit. <br /> Future risk to the producing aquifer through the South Well is minimal for the following <br /> reasons: <br /> • Ground water contaminant levels have decreased dramatically at MW-IA, installed <br /> adjacent.to the former UST location. The levels are expected to continue to decline <br /> over time as natural attenuation processes operate. The degradation of residual <br /> contamination will also decrease the likelihood of contaminant migration. Thus, the <br /> potential risk to the South Well will continue to decline as the residual contaminants <br /> are naturally attenuated. <br />