Site Assessment Work Plan Advanced Environmental Concepts, Inc. <br /> V <br /> Exposure Monitoring Plan: <br /> Air monitoring will be conducted during excavation procedures using a TIPrmll Photoionization <br /> Detector (PID) equipped with a 10.6eV lamp, manufactured by Photovac, Inc. The PID will be <br /> calibrated to 50 ppm hexane. These air monitoring procedures will be carried out in accordance <br /> with San Joaquin Valley Unified Air Pollution Control District (SJVUAPCD) guidelines. Volatile <br /> emissions are not anticipated but will nevertheless be monitored. <br /> Imp Personal Protective Eauloment: <br /> When handling samples, the on-site Geologist will wear latex gloves. Hard hats will be worn by <br /> all personnel on-site when in proximity of excavation equipment. <br /> Work Zones and Security Measures: <br /> V <br /> Access to the site will be restricted to authorized personnel. A set of cones, placards or wide <br /> yellow tape, surrounding the site,will define the perimeter, if needed. The Project Manager will <br /> ,r be responsible for site security. <br /> Decontamination Measures: <br /> Avoidance of contamination whenever possible is the best method for protection. Common sense <br /> dictates that on-site personnel avoid sitting, leaning or placing equipment on possible <br /> contaminated soil. All personnel will be advised to wash their hands, neck and face with soap <br /> �• and water before taking a break or leaving the site. <br /> General Safe Work Practices: <br /> On-site personnel will be briefed each day in "tailgate" meetings as to the day's goals and <br /> equipment to be used. Anticipated contaminants and emergency procedures will be reviewed. <br /> Appropriate personal protective equipment will be put on and verified correct by SSO, including <br /> `r respirator fit. <br /> Excavation and sampling equipment will be steam-cleaned before being brought on-site. The <br /> on-site Geologist will oversee operations and log the excavation strata. The Sample Coordinator <br /> will assure that proper protocol is used at all times in collecting and handling samples. <br /> Training Reauirements: <br /> The SSO will conduct a pre-site training session which will include all points of MSDS forms, <br /> contaminant properties, warning signs, health hazard data, risk from exposure and emergency <br /> first aid. <br /> All chemicals are to be covered and the SSO will assure that everyone fully understands site <br /> hazards. <br /> Project: AEC 96C-9707 3 <br />