Laserfiche WebLink
CGeological TecknicsInc. Page 3 <br /> ' Groundwater Monitoring Report <br /> Project No. 1030.2 <br /> May 7,2003 <br /> ' A Waterra um and dedicated tubing were used to collect each sample. Extreme care was <br /> pump g <br /> exercised while collecting samples to prevent agitation of the water contained in the <br /> ' Waterra pump. With minimal sample aeration, water samples were transferred from the <br /> pump into 40-m1 VOA vials preserved with hydrochloric acid or trisodiuin phosphate. <br /> Additional samples were collected in I-pint plastic bottles for natural attenuation <br /> parameters. All samples were checked for headspace bubbles, labeled, inserted into foam <br /> holders and placed into a cooled ice chest for transport to the laboratory. <br /> ' The sampling technician wore disposable gloves while collecting all samples. <br /> ' A chain of custody document, listing all samples collected and their intended analyses, <br /> accompanied the samples from field to the laboratory, thereby providing a means to track <br /> the movement of and ensure the integrity of the samples. <br /> ' 1.3 Groundwater Laboratory Analyses <br /> ' 1.3.1 Sherwood Labs <br /> Groundwater samples collected on January 29, 2003, were delivered to Sherwood Labs of <br /> Hilmar, California (certification #1400) for analyses of- <br /> • Benzene, Toluene, Ethyl Benzene, and Xylene (BTEX) by EPA method 8020 <br /> • Gasoline Range Organics (TPH-G) by EPA method 8020/8015(M) <br /> ' • Volatile Organic Compounds by EPA method 8260 <br /> u MTBE, ETBE, TAME,D1PE, TBA, 1,2 DCA, EDB <br /> ' The results of the laboratory analyses are listed in Table 3 of Appendix A. Detection limits <br /> and analytical results are presented in Appendix B. <br /> ' The analytical data were submitted to GeoTracker as required under AB 2886 on February <br /> 17, 2003. The confirmation code for the submittal is 6351993501. <br /> ' Additional groundwater samples collected on January 29, 2003, were delivered to Far West <br /> Laboratories, Inc. of Riverbank, California (certification #1310) for analyses of- <br /> ' • Total Alkalinity—by EPA method 2320B <br /> • Conductivity—by EPA method 2510B <br /> • Total Iron—by EPA method 200.7 <br /> ' S.. -Sulfate —by EPA.method 300.0 <br /> • Nitrate as nitrogen—by EPA method 300.0 <br /> ' The results of the laboratory analyses are listed in Table 4 of Appendix A. Detection limits <br /> and analytical results are presented in Appendix B. <br />