Laserfiche WebLink
Geologual nclm cs lnc Page 2 <br /> Groundwater Momtonng Report <br /> Project No 662 2 <br /> November 30,2001 <br /> October 12, 2001 was approximately 14 62 feet above MSL, which is about 24 feet below <br /> ' ground surface <br /> A groundwater gradient was calculated for the October 12, 2001 monitoring event and <br /> ' found the groundwater to be flowing N88°E at 0 0014 ft/ft Groundwater elevation and <br /> gradient data are summarized in Table 1, Appendix A Gradient direction is shown on <br /> Figure 2 Gradient Map, and Figure 3 Groundwater Gradient Rose Diagram <br /> 1.2 Groundwater Samphng Procedure <br /> ' On October 12, 2001, Don Light of Del-Tech mobilized to the site to conduct a groundwater <br /> monitoring of the three existing monitoring wells on site <br /> Before sampling was performed the wells were sounded for depth to water and then a clear <br /> disposable bailer was used to determine if floating product was present The wells were <br /> purged of at least three well volumes of stagnant water using a dedicated Waterra check-ball <br /> assembly and 1/2 inch tubing Purging continued until the temperature, conductivity, and pH <br /> of the groundwater stabilized (c10% variation between three readings) indicating that <br /> formation water representative of aquifer conditions was entering the wells These water <br /> quality parameters were measured at intervals of each well volume purged <br /> ' Once purging was complete, a water sample was collected from the Waterra tube Care was <br /> taken to minimize sample agitation Once the sample container was filled and capped, the <br /> bottle was inverted, tapped, and checked for headspace bubbles The sample container was <br /> ' identified and labeled with a unique designation, inserted into foam holders and placed in an <br /> ice chest cooled to 4°C for transport to the laboratory <br /> ' All non-disposable sampling equipment was decontaminated using a hot water washer and <br /> detergent before and between uses Disposable gloves were used by the technician to <br /> collect all samples and were changed with each sample collection <br /> ' A chain of custody document, listing all samples collected, accompanied the samples from <br /> field to laboratory, thereby providing a means to track their movement and insure their <br /> integrity <br /> ' All water purged from each monitoring well and not used as a sample, was placed in a 55 <br /> gallon DOT approved container, properly labeled and stored on site until its proper <br /> disposition can be arranged <br /> Groundwater monitoring field logs are included in Appendix C <br /> t <br />