Laserfiche WebLink
Alpha Analytical, Inc. <br /> ( I� 255 Glendale Ave. • Suite 21 • Sparks,Nevada 89431-5778 <br /> (775)355-1044• (775)355-0406 FAX• 1-800-283-1183 <br /> ate: Work Order: <br /> Dec-05 QC Summary Report 05120803 <br /> Method Blank Type:MBLK Test Code:EPA Method SW8015B/DHS LUFT Manual <br /> File ID:C:IHPCHEM1MS071DATA1051208105120807.D Batch 1D:MS07A1208B Analysis Date: 12/08/2005 10:17 <br /> Sample ID: MBLK MS07A1208B Units:mg/m3 Run ID:MSD_07_051208B Prep Date: 12/08/2005 <br /> Analyte Result PQL SpkVal SpkRefVal %REC Lowl-imit HighLimit RPDRefVal %RPD(Limit) Qual <br /> TPH Purqeable ND 10 <br /> Surr: 1,2-Dichloroethane-d4 1.91 2 96 76 127 <br /> Surr:Toluene-d8 1.91 2 96 84 113 <br /> Surr:4-Bromofluorobenzene 1.96 2 98 79 119 <br /> Laboratory Control Spike Type:LCS Test Code:EPA Method SW8015B/DHS LOFT Manual <br /> File ID:C:IHPCHEMWS071DATA1051208105120805.D Batch ID:MS07AI20813 Analysis Date: 12/08/2005 09:35 <br /> Sample ID: GLCS MS07A1208B Units:mg/m3 Run ID:MSD_07_0512088 Prep Date: 12/08/2005 <br /> Analyte Result PQL SpkVal SpkRefVal %REC Lowl-imit HighLimit RPDRefVal %RPD(Limit) Qual <br /> TPH Purqeable 412 10 400 103 78 127 <br /> Surr: 1,2-Dichloroethane-d4 9.32 10 93 76 127 <br /> Surr:Toluene-d8 9.5 10 95 84 113 <br /> Surr: 4-Bromofluorobenzene 9.82 10 98 79 119 <br /> Comments: <br /> Calculations are based off of raw(non-rounded)data.However,for reporting purposes,all QC data is rounded to three significant figures.Therefore,hand calculated <br /> values may differ slightly. <br /> I <br />