My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0013073
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2969
>
3500 - Local Oversight Program
>
PR0545428
>
ARCHIVED REPORTS_XR0013073
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 6:58:56 PM
Creation date
3/9/2020 10:55:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0013073
RECORD_ID
PR0545428
PE
3528
FACILITY_ID
FA0005487
FACILITY_NAME
MARCIS DIESEL SERVICE
STREET_NUMBER
2969
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
2969 LOOMIS RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N./ <br /> i,..y <br /> recorded an average water table depth of about 70' bgl. It was measured at an average depth of <br /> 59.01' bgl in July, 1998. <br /> LOCATION OF WELLS WITHIN 2,000 FEET OF PROPERTY: <br /> The attached EXHIBIT A lists wells identified by the California Division of Water Resources. <br /> Field investigation reveals that the list is incomplete. We have completed a survey of the area to <br /> locate existing wells. The results of that survey are shown on PLATE I It shows allot the wells <br /> which were visible from close observation; there may be others which could not be identified. <br /> PRIOR USE OF UST'S: <br /> Two, 5,000 gallon UST's which had been used for storing diesel fuel were removed from the <br /> property in March, 1987. There are no records concerning amounts of fuel used during the time <br /> the tanks were in service. <br /> SUMMARY OF PRIOR EVENTS: <br /> March, 1987 - Two 5,000 gallon diesel UST's removed from site. Some contamination <br /> measured in soil samples taken after tank removal. <br /> March, 1988 - Site of removed UST's reentered. Soil samples taken at 28'& 29' below grade. <br /> Xylene& TVPH measured in both samples. Excavation filled with clean soil. <br /> April 3, 6, & 7, 1992 - Three (3) groundwater monitoring wells placed on site to depths of 84', <br /> 86', & 89'. Refer to WJH report titled "Groundwater Investigation Report"dated May, 1992 <br /> for details of that work. <br /> May 30, 1996 - One(1) soil boring was advanced to 80' bgl; it was located in the area which <br /> had been occupied by the diesel UST's. Minor amounts of ethylbenzene were measured at 31', <br /> 36',41',& 56'. Low levels of xylene was detected at 311, 361, 411, 461, 511, 56,61', & 71'. TPH as <br /> gasoline was measured in samples taken from 31' to 71', and at 80'. Significant levels of TPH as <br /> diesel were measured in all samples taken. TABLE I summarizes the results of that work, and <br /> also MW-1 & MW-4. Refer to the Lush Geosiences report titled "Interim Investigation Report <br /> Marci's Diesel Service", dated August 17, 1996 for details. <br /> October 10, 1996 - MW-1 was purged and sampled by Del-Tech Geotechnical Support <br /> Services, but the laboratory results were considered inaccurate due to apparent contamination of <br /> sampling equipment. <br /> November 27, 1996 -MW-1 was resampled by Del-Tech. Laboratory results revealed the <br /> following; benzene-ND, toluene -ND, ethylbenzene- 0.4 ug/L, xylene - 0.8 ug/L, and TPHg - <br /> 222 ug/L. TEPH was ND, and MTBE was not identified. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.