My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_FILE 1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
3500 - Local Oversight Program
>
PR0545509
>
FIELD DOCUMENTS_FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2020 8:56:34 AM
Creation date
3/10/2020 3:11:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
FIELD DOCUMENTS
FileName_PostFix
FILE 1
RECORD_ID
PR0545509
PE
3528
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
02
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1 <br /> WELL COMPLETION DETAILS <br /> Jamar Service Station, 4075 East Main Street, Stockton, CA <br /> Page 1 of 2 <br /> Base of <br /> Well Top of Screen Screen <br /> Casing Interval or Interval or Length of <br /> Total Well Depth Size Top of Base of Screen or <br /> /(Maximum (Inside Injection Injection Injection <br /> General Installation Installation Sounded Depth) Diameter Well Casing Sparge Point Sparge Point Sparge Point <br /> Well# Location Well Type Date Oversight By: (feet bgs) in Inches) Material Screen I Completion Type (feet bgs) (feet bgs) (feet) <br /> J.P.Cummings& Factory Slotted-Unknown <br /> MWt On Site GWM 8/19/1999 Associates 74/(73.54) 2 Sch 40 PVC Slot Size 54 74 5 • <br /> MW1 c On Site GWM 11129/2010 ATC 109.5/(109.38) 2 Sch 40 PVC 0.020"Factory Slotted 104.5 109.5 5 <br /> J.P.Cummings& Factory Slotted-Unknown <br /> MW2 On Site GWM 9/21/1999 Associates '74/(74.60)' 2 Sch 40 PVC Slot Size 54' 74 20 <br /> J.P.Cummings& Factory Slotted-Unknown <br /> MW3 On Site GWM 9/21/1999 Associates 71/(70.52) 2 Sch 40 PVC Slot Size 51 71 20 <br /> MW3c On Site GWM 12/3/2010 ATC 111.5 1(109.98) 2 Sch 40 PVC 0.020"Factory Slotted 105 110 5 <br /> J.P.Cummings& Factory Slotted-Unknown <br /> MW4 On Site GWM 8/21/2000 Associates 75/(74.66) 2 Sch 40 PVC Slot Size 55 75 20 <br /> J.P.Cummings& Factory Slotted-Unknown <br /> MW5 On Site GWM 8/22/2000 Associates '70/70.5 1)2 2 Sch 40 PVC Slot Size 50' 70 20 <br /> MW6a Off Site GWM 5/20/2003 GHH 75/(74.34) 2 Sch 40 PVC 0.020"Factory Slotted 55 75 20 <br /> MW6b Off Site GWM 5/20-21/03 GHH '94/(94.33)' 2 Sch 40 PVC 0.020"Factory Slotted 89 94 5 <br /> MW6c Off Site GWM 4/16/2004 ATC 1101(107.41) 2 Sch 40 PVC 0.020"Factory Slotted 105 110 5 <br /> MW7a Off Site GWM 5/21-22/03 GHH 74.51(74.28) 2 Sch 40 PVC 0.020"Factory Slotted 55 75 20 <br /> MW7b Off Site GWM 5122-23/03 GHH `94/(94.20) 2 Sch 40 PVC 0.020"Factory Slatted 89 94 5 <br /> MW7c Off Site GWM 2/25/2004 ATC 105/(103.87) 2 Sch 40 PVC 0.020"Factory Slotted 100 105 5 <br /> MW8 On Site GWM 2/17/2004 ATC 110/(106.36) 2 Sch 40 PVC 0.020"Factory Slotted 100 105 5 <br /> MW9a Off Site GWM 4/12/2004 ATC 75.50/(74.01) 2 Sch 40 PVC 0.020"Factory Slotted 55 75.5 20.5 <br /> MW9b Off Site GWM 4/12/2004 ATC 94.00 1(92.70) 2 Sch 40 PVC 0.020"Factory Slotted 89 94 5 <br /> MW9c Off Site GWM 2/18/2004 ATC 110/(107.1) 2 Sch 40 PVC 0.020"Factory Slotted 105 110 5 <br /> MW10a Off site GWM 4/12/2004 ATC 75.50/(73.39) 2 Sch 40 PVC 0.020"Factory Slotted 55 75.5 20.5 <br /> MW10b Off Site GWM 4/15/2004 ATC 951(94.45) 2 Sch 40 PVC 0.020"Factory Slotted 90 95 5 <br /> MW10c Off Site GWM 4/1612004 ATC 110(107.21) 2 Sch 40 PVC 0.020"Factory Slotted 105 110 5 <br /> MW11c Off Site GWM 11/23/2010 ATC 111/(110.7) 2 Sch 40 PVC 0.020"Factory Slotted 106 111 5 <br /> MW12a On Site GWM 12/6/2010 ATC 751(74.96) 2 Sch 40 PVC 0.020"Factory Slotted 55 75 20 <br /> EW-1 On She GWM 5/19/2003 GHH '741(74.67)° 4 Sch 40 PVC .030 Factory Slotted 54 74 20 <br /> IWI -Deep 0.75 Sch 80 PVC 1"Ozone Diffuser 105.2 107.7 2.5 <br /> IW1 -Shallow On Site AS INJ 1/16/2004 ATC 110.5 0.75 Sch 80 PVC 1"Ozone Diffuser 71.5 74.0 2.5 <br /> IW2-Deep 0.75 Sch 80 PVC 1"Ozone Diffuser 105.2 107.7 2.5 <br /> IW2-Shallow On Site AS INJ 1/21/2004 ATC 110.5 0.75 Sch 80 PVC 1"Ozone Diffuser 71.5 74.0 2.5 <br /> IW3-Deep 0.75 Sch 80 PVC 1"Ozone Diffuser 104.7 107.2 2.5 <br /> IW3-Shallow On Site AS INJ 1/15/2004 ATC 110.0 0.75 Sch 80 PVC 1"Ozone Diffuser 71.0 73.5 2.5 <br /> IW4-Deep 0.75 Sch 80 PVC 1"Ozone Diffuser 105.2 107.7 2.5 <br /> IW4-Shallow On Site AS INJ 1/14/2004 ATC 110.5 0.75 Sch 80 PVC 1"Ozone Diffuser 71.5 74.0 2.5 <br /> IW5-Shallow 0.75 Sch 80 PVC 1"Ozone Diffuser 71.5 74.0 2.5 <br /> IW5-Deep On Site AS INJ 1/19/2004 ATC 110.5 0.75 Sch 80 PVC 1"Ozone Diffuser 105.2 107.7 2.5 <br /> IM-Shallow On Site AS INJ 12/1/2010 ATC 77.5 3 Sch 80 PVC 0.020"Factory Slotted 72.5 77.5 5 <br /> IW7-Shallow On Site AS INJ 12/6/2010 ATC 75 3 Sch 80 PVC 0.020"Factory Slotted 70 75 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.