My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005220
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2900 - Site Mitigation Program
>
PR0541650
>
ARCHIVED REPORTS_XR0005220
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2020 6:04:43 PM
Creation date
3/11/2020 2:51:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005220
RECORD_ID
PR0541650
PE
2960
FACILITY_ID
FA0023868
FACILITY_NAME
FORMER USA GASOLINE SERVICE STATION 110
STREET_NUMBER
2132
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
1730635
CURRENT_STATUS
01
SITE_LOCATION
2132 E MARIPOSA RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.2 Site History <br /> Two phases of site assessment have been performed at this facility The first, as part of a pre- <br /> purchase due diligence by Pacific Environmental Group, consisted of the drilling and sampling <br /> of four soil bonngs, one of which was completed as a groundwater monitoring well <br /> Groundwater was present at about 45 feet bgs Soil sample analyses from these bonngs indicated <br /> that there were TPH and BTEX constituents present in shallow soils and soils dust above the <br /> water table One groundwater sample contained BTEX compounds above state action levels <br /> The presence of petroleum hydrocarbon compounds in the soil and groundwater beneath the site <br /> prompted a second site assessment conducted by Applied GeoSystems This second phase of <br /> work consisted of the drilling and installation of two additional groundwater monitoring wells <br /> Groundwater sample analyses from these wells confirmed that TPH compounds were present in <br /> the groundwater beneath the site The direction of groundwater movement was calculated to be <br /> in a north-westerly direction <br /> As a result of these findings PHS/EHD requested that a quarterly groundwater monitoring <br /> program be initiated for this location, plus a request that all domestic groundwater wells be <br /> identified and sampled Six domestic wells were located and sampled Test results presented <br /> in a May 13, 1987 letter report prepared by Applied GeoSystems were non detect for TPH and <br /> BTEX The next quarterly sampling could not be performed because the groundwater table had <br /> declined below the bottom of the monitoring wells <br /> 2.3 AREA BACKGROUND <br /> Prior consultants have indicated that all four corners at the intersection have had operating retail <br /> gasoline service stations on them at one time or another No site assessments have been <br /> performed at any of these other corners <br /> The northwest corner is occupied by an abandoned Chevron service station Thi's station is <br /> fenced in with an open pit where underground tanks have been removed A record review of <br /> County files indicates that there is an outstanding request for further characterization at this site <br /> The southwest corner is reported to be the site of a former Shell service station The property <br /> is presently an open field with no indication of prior use A review of County records did not <br /> produce any information about this property <br /> The southeast corner has what appears to be an abandoned gasoline service station The property <br /> is fenced A review of agency files did not produce any information about this property A <br /> discussion with County staff yielded a recollection that the property owner had been queried <br /> about the presence of underground tanks on site and the County had been informed that all tanks <br /> had been removed No verification was apparently provided and no follow-up was ,performed <br /> • <br /> A 1125J1 WP 3 <br /> 1 <br />