0 <br /> Gabriel Gonzalez [EH] <br /> From: Adrienne Ellsaesser [EH] <br /> Sent: Wednesday, February 25, 2015 12:12 PM <br /> To: Munn, Julie <br /> Cc: Sobieraj, Justin; Gabriel Gonzalez [EH];John Yoakum [EH] <br /> Subject: RE: 437 E Miner Ave., Stockton - auger size question <br /> Hi Julie, <br /> 16 inch augers. The problem is the auger walks off the top of the well to the side of it.This changes the angle of the <br /> auger such it will miss the well casing entirely, as the auger travels downwards.The larger 16 inch auger will still travel <br /> across the path of the well casing, after it walks off the center of the well. <br /> Adrienne <br /> From: Munn, Julie [mailto:Julie.D.Munn@arcadis-us.com] <br /> Sent: Wednesday, February 25, 2015 10:41 AM <br /> To: Adrienne Ellsaesser [EH] <br /> Cc: Sobieraj, Justin <br /> Subject: RE: 437 E Miner Ave., Stockton - auger size question <br /> Hi Adrienne-we are starting to plan for this project again and I was going over your email below and noticed you said: <br /> We are requiring wells 5P-1B,SP-3A,5P-5A,5P-5B, 5P-5C,SP-6A, 5P-6B, SP-6C AND SP-4A be removed, by over <br /> drilling with an augur two times the original borehole diameter. <br /> These wells were installed with 8-inch augers. Are you saying they have to be drilled out with 16" augers or do you <br /> mean two times bigger i.e. 10 or 12-inch? There is a huge difference so I want to be certain. Please advise. <br /> Thank you, <br /> From: Adrienne Ellsaesser [EH] [mailto:AEllsaesserCalsicehd.com] <br /> Sent: Friday, October 17, 2014 10:32 AM <br /> To: McGovern, Cameron <br /> Cc: BWaiteCalchevron.com; mcmillans521Ca@ahoo.com; Munn, Julie; Sobieraj, Justin; Gabriel Gonzalez [EH]; John Yoakum <br /> [EH]; Rogers,Tamera; Vance Wong [EH] <br /> Subject: RE: 437 E Miner Ave., Stockton <br /> Good Morning Cameron, <br /> I have spoken with my staff regarding this project. Based on the field observations made by my staff (and as we <br /> have experienced in the past) the neat cement grout was not successfully and confidently pumped down to full <br /> depth and up to surface grade of SP-4A. It was gravity fed, after attempts to pump the grout down the well <br /> failed. Additionally, the grout mixture used to seal this well did not meet the standards for an approved seal <br /> mixture,as additional water was used to dilute the mixture. <br /> We are requiring wells 5P-18,5P-3A,5P-5A,SP-5B, SP-5C,5P-6A, 5P-6B, SP-6C AND 5P-4A be removed, by over <br /> drilling with an augur two times the original borehole diameter. <br /> 1 <br />