Project No. 034-17016 <br /> Site-Specific Health& Safety Plan <br /> Page No. 10 <br /> • Due to the possibility that VOCs from maintenance operations may have been discharged to the <br /> waste oil tank,one(1)soil vapor boring will be completed to a depth of 5.5 feet bgs and one(1)soil <br /> vapor sample will be collected and analyzed for VOCs. <br /> AREA OF FUEL DISPENSERS <br /> • Two(2)soil borings will be completed to a depth of five(5)feet bgs,one boring adjacent to each of <br /> the two(2) fuel dispensers. <br /> • Soil samples will be collected from depths of two(2)and five(5)feet bgs for a total of two(2)soil <br /> samples from each boring. <br /> • Four(4) soil samples from the fuel dispensers will be submitted for analysis of TPH-d and VOCs. <br /> AREA OF PRODUCT LINES <br /> • Four(4)borings will be completed to a depth of five(5)feet bgs adjacent to the inferred location of <br /> the product lines connecting the 20,000-gallon diesel USTs to the fuel dispenser island. <br /> • Soil samples will be collected from depths of two(2)and five(5)feet bgs for a total of two(2)soil <br /> samples from each boring. <br /> • A total of eight(8)soil samples from the product line areas will be submitted for analysis of TPH-d <br /> and VOCs. <br /> 2. TRUCK MAINTENANCE SHOP TRENCH DRAINS, OIL/WATER SEPARATORS/ <br /> CLARIFIERS/SUMPS <br /> The investigation within the truck maintenance shop will include the surface staining near the trench drains, <br /> grated drain/sump located within a lube pit,oily liquid located with the lube pit sump, subsurface clarifiers <br /> located within the maintenance shop building, and oil/water separator located outside of the truck <br /> maintenance shop building. The scope of work for the investigation includes the following: <br /> • Ten(10)soil borings will be completed in the truck maintenance shop area as follows: <br /> o Two(2)soil borings will be completed to a depth of five(5)feet bgs in the stained areas near <br /> the trench drains. Soil samples will be collected at depths of two(2)and five(5) feet bgs. <br /> o One(1)soil boring will be completed to a depth of five(5)feet bgs in the stained area next <br /> to the drain/sump located in the lube pit. Soil samples will be collected at depths of two(2) <br /> and five(5)feet bgs. <br /> o Four(4)soil borings will be completed to a depth of 10 feet bgs,one(1)adjacent to each of <br /> the four(4)interior subsurface clarifiers in the truck maintenance shop area. Soil samples <br /> will be collected at depths of five(5)and 10 feet bgs. <br /> o Two(2)soil borings will be completed to a depth of 10 feet bgs as close as practical to the <br /> outside oil/water separator. Soil samples will be collected at depths of five(5)and 10 feet <br /> bgs. One(1)of the soil borings will be deepened to a depth of approximately 20 to 30 feet <br /> bgs and a grab groundwater sample will be collected and analyzed for TPH-cc,VOCs,CAM <br /> 17 metals,and PCBs,and VOCs. Depending on the results of field screening,a soil sample <br /> may be collected from the capillary fringe and analyzed for TPH-cc,VOCs,CAM 17 metals, <br /> and PCBs. <br /> o One (1) soil vapor boring will be completed to a depth of 5.5 feet bgs near the outside <br /> oil/water separator. One(1)soil vapor sample will be collected and analyzed for VOCs. <br /> KRAZAN&ASSOCIATES,INC. <br /> With Offices Serving the Western United States <br /> 03417016 SSI La hu p HASP Fiml.doc <br />