First Quarter 1995 Status Report 3 <br /> Golden Grain Company, Manteca Bean Facility,229 Moffat Blvd , Manteca,CA April&, 1995 <br /> ■ checking and calibrating the system lower explosive limit (LEL) meters <br /> ■ recording operational data and maintaining vacuum extraction blowers and vapor <br /> extraction system (VES) <br /> r checking and recording operational data for the air stripper and making adjustments as <br /> necessary <br /> ■ checking the condition of the catalytic water conditioner which minimizes fouling caused <br /> by the hardness of the water <br /> ■ performing a dally system operating parameters check via modem <br /> The soil vapor extraction and groundwater treatment systems ran continuously this quarter except <br /> during four occasions The following is a list of the days that the remediation system was not <br /> operational <br /> 01/01/95-01/11/95 The groundwater extraction system was non-operational because <br /> the relay from the phase converter to the air stripper blower failed <br /> A new relay had to be ordered prior to replacement The soli vapor <br /> extraction system continued to operate during the groundwater <br /> extraction system down time <br /> 01/21/95-01/25/95 The groundwater extraction system was non-operational because <br /> the discharge line became clogged with calcium carbonate chips <br /> from the air stripper trays The chips were removed, the air stripper <br /> plates were cleaned, and the system was restarted The soil vapor <br /> extraction system continued to operate during the groundwater <br /> extraction system down time <br /> 02/20/95-02/22/95 The fresh air bleed to the soil vapor extraction system was tripped <br /> for an unknown reason and the groundwater extraction system was <br /> shut down by the safety interlocks The system was restarted within <br /> two days of the system shutdown <br /> 02/26/95-02/28/95 A blown fuse in the catalytic oxidizer control panel caused the soil <br /> vapor extraction system to shut down and the groundwater system <br /> was shut down by the safety interlocks The fuse was replaced and <br /> the system was restarted within two days of the system shutdown <br /> During this quarter of operation, there were no releases of untreated groundwater or untreated <br /> system effluent vapors except for a 2 0 p g/L detection of xylenes in the effluent vapor during the <br /> February 22, 1995, sampling event System shutdowns were planned or occurred as a result of <br /> designed system safety interlocks, which shut down the remediation systems to preclude untreated <br /> . releases The xylenes detected in the catalytic oxidizer effluent was below the permit discharge limit, <br /> 0102no13 lox <br /> GROUNDWATER <br /> TECHNOLOGY, INC <br />