detected at a level of 5,000 ppmv or more,obtain fixed and biogenic gas valves or the equivalent; <br /> (e.g.,oxygen,carbon dioxide,methane,and ethylene)data by using a <br /> Thermal-Conductivity Detector(TCD)or a hand-held instrument.The RL b. 100-mL gas-tight syringe fitted with an inert valve and wrapped in <br /> for oxygen and carbon dioxide should be one percent or less. aluminum foil; <br /> E. Pressure Reading: Record pressure readings of each sampling tube c. Gas-tight glass bulb wrapped in aluminum foil;or <br /> system in the field logs and report along with the methane concentration to <br /> determine if the area is pressurized d. Glass-lined or silicon coated SUMMA'S canister. <br /> F. Special GC Requirements:The GC method requires calibration curves D. Precautions <br /> for analytes such as methane since it is not a normal target analyte for <br /> such an analytical method. a. Hydrogen sulfide is extremely unstable in the presence of oxygen and <br /> moisture;therefore,avoid contact of hydrogen sulfide samples with <br /> G. Special Hand-Held Instruments Requirements:Hand-held instruments oxygen and moisture. <br /> should be calibrated in accordance with the manufacture's instructions. <br /> When a hand-held instrument is used to analyze methane samples, b. Due to the high reactivity of hydrogen sulfide gas,avoid contact of <br /> confirm at least 10 percent of all positive methane samples(e.g.,more hydrogen sulfide samples with metallic or other non-passive surfaces <br /> than 5,000 ppmv),rounded to the nearest whole number,by another during sample collection,storage,and analysis. <br /> hand-held instrument(different unit or brand)or by a GC method. <br /> c. Care must be taken so that GC components do not react with the <br /> 2. Hydrogen Sulfide Sampling Program:Hydrogen sulfide may be analyzed sample. Typically glass-lined injection ports and Teflon"tube packed <br /> by a GC using the South Coast Air Quality Management District(SCAQMD) columns are used to avoid loss of hydrogen sulfide due to reaction with <br /> Method 307-91 or EPA Method 16,or by an appropriate hand-held instrument active surfaces. <br /> (e.g.,LTX-310 calibrated for hydrogen sulfide,Jerome 631-X or Drager TM <br /> tubes). 4.0 Analytical Result Reporting: <br /> A. Reporting Limit The RL should be equal to or less than 0.5 ppmv or be Consult Appendix H for reporting format and parameters. <br /> sensitive enough to allow for a modeled ambient air concentration(at least <br /> one microgram per cubic meter)at the soil surface. <br /> B. Holding Time:Hydrogen sulfide samples should be extracted directly into <br /> a hand-held analyzer within 30 minutes of collection to minimize the risk of Nlz , q <br /> losing the hydrogen sulfide due to reaction with active surfaces. If a hand- ' " <br /> held instrument is not used,hydrogen sulfide samples should be analyzed Z V ' <br /> as below: <br /> a. Within 30 minutes of collection,using the GC procedures;or <br /> b. Within 24 hours of collection,if a surrogate is added to the samples or <br /> > <br /> 100 percent duplicate samples are collected. <br /> C. Sample Containers:The following sample containers are recommended <br /> for hydrogen sulfide: <br /> a. Minimum one(1)liter black Tedlaro bag fitted with polypropylene <br /> 12/10/2009 -43- 12/10/2009 44- <br />