Laserfiche WebLink
are detected in the soil gas samples,fixed and biogenic gas(oxygen, <br /> 3.8 Soil Gas Sample Analysis: carbon dioxide,and methane)data should be obtained using a Thermal- <br /> Conductivity Detector(TCD)or a hand-held instrument; <br /> 1. VOC Samples:All VOC samples should be analyzed using only a Gas <br /> Chromatograph/Mass Spectrometer(GC/MS)method(e.g., EPA Method C. At petroleum contaminated sites(including oilfields),concentrated animal <br /> 82608,used for analysis of soil gas samples,EPA Method TO-15,TO-17 or facilities and operations,wetlands,landfills or other sites where the <br /> equivalent),except at well-characterized sites(e.g.,VOCs are known to be presence of methane and/or hydrogen sulfide is suspected,soil gas <br /> present and confirmed based on previous GC/MS analyses). A non-GC/MS samples should be analyzed for methane and/or hydrogen sulfide; <br /> method(e.g., EPA Method 8021 B,used for analysis of soil gas samples)may <br /> be used only for routine monitoring of VOC contamination at well- D. At sites where use of chlorinated solvents with 1,4-dioxane is suspected or <br /> characterized sites. Sample introduction methods(i.e.,TO-15,TO-17,TO- known to exist,soil gas samples should be analyzed for 1,4-dioxane at a <br /> 13A,and modified GC methods such as EPA Methods 8015 an 8021)and reporting limit which is health protective. <br /> their advantages and disadvantages are further discussed in Appendix F. <br /> Detailed discussion is provided in Appendix E for specifics concerning soil 5. Auto samplers:Auto samplers for Method 5030/8260B are not <br /> gas containing naphthalene. recommended;and therefore,this technique should not be used because <br /> transfer of sample from a soil gas collection vessel such as syringes to <br /> If during routine monitoring,new VOC(s)were detected by a non-GC/MS another secondary container(e.g.,VOA-vials)may result in sample loss <br /> method,then at least 10 percent of the samples with each newly identified (See Appendix F). Furthermore,auto samplers are not capable of <br /> VOCs should be confirmed by a GUMS method. Thereafter,routine handling variable volumes of soil gas sample,especially larger sample <br /> monitoring can resume with the non-GC/MS method,including the new volumes,to adjust for the desired RLs for the site-specific compounds of <br /> analyte(s). potential concern. <br /> 2. VOCs:Identify all quantifiable VOCs and report all results 3.9 Methane and Hydrogen Sulfide Sampling Programs: <br /> Include the estimated results of all Tentatively Identified Compounds[TICs]) If the presence of methane and/or hydrogen sulfide is suspected,they should <br /> detected in the report. If TICs are identified,contact the regulating agency to also be included in the analytical plan. <br /> determine whether additional action is required(e.g.,running additional <br /> standards to quantify TICs)and whether the use of these estimated data for 1. Methane Sampling Program:Methane samples may be analyzed by a GC <br /> risk evaluation is appropriate. using modified EPA Method 8015B,EPA Method TO-3,EPA 3C,or by Land <br /> Tech Gas Analyzer GA-90,Gas Emissions Monitor GEM-500,GEM-2000 or <br /> 3. Leak Check Compounds:All results should be reported as specified in other appropriate hand-held instruments. <br /> Section 2.4 <br /> A. Reporting Limit:The RL for methane analysis should not exceed 500 <br /> 4. Specific Compounds:Based on the site history and conditions,analyses for parts per million by volume(ppmv). <br /> specific compounds may be required by the regulating agency staff. <br /> B. Methane Sample Containers:In addition to the gas-tight sample <br /> Examples include: containers previously specified in Section 2.7,Tedlar°bags may be used <br /> for collection of methane samples with a holding time of no more than 24 <br /> A. In areas where USTs or fuel pipelines are identified,soil gas samples hours. <br /> should be analyzed for oxygenated compounds(e.g.,methyl tertiary butyl <br /> ether(MTBE),ethyl tertiary butyl ether(ETBE),di-isopropyl ether(DIPE), C. Methane Screening Level:When methane is detected at 1,000 ppmv or <br /> tertiary amyl methyl ether(TAME),tertiary butyl alcohol(TBA),and more,additional sampling and/or further investigation is recommended to <br /> ethanol]; identify the source(s). <br /> B. At oilfield sites where semi-VOCs or total petroleum hydrocarbons(TPHs) D. Fixed and Biogenic Gases:At sites where methane is investigated and <br /> 12/10/2009 -41 - 12/10/2009 -42- <br />