Laserfiche WebLink
L-..1....a� <br /> SWRCB,January 2002 a of <br /> MAY ��� <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: X Piping Manufacturer _l Industry Standard L P� 'sign;,Mt _ <br /> ❑Other(Spec) <br /> Test Method Used: X Pressure ❑Vacuum Cl Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Pressure Gauges in Psi/Nitrogen Equipment Resolution: 1/10-15 Psi <br /> Piping Run# 1 Piping Run#2 Piping Run-#3 Piping Run#4 <br /> Piping Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Piping Manufacturer: Ameron Ameron Ameron Ameron <br /> Piping Diameter: 2" 2" 2" 3"x 2" <br /> Length of Piping Run: Approx.200' Approx.185' Approx. 185' Approx.215' <br /> Product Stored: Regular 87 Super 91 Diesel Gasoline Vapor <br /> Method and location of Clam Shell Test Port Clam Shell Test Port Clam Shell Test Port Clam Shell Test Port <br /> piping-run isolation: at STP Sum #1 at STP Sum #2 at STP Sump#3 at STP Sum #1 <br /> Wait time between applying 10 Minutes 10 Minutes 10 Minutes 10 Minutes <br /> pressure and starting test: <br /> Test Start Time: 8:50 9:00 9:10 9:20 <br /> Initial Reading(Ri): 5 Psi 5 Psi 5 Psi 5 Psi <br /> Test End Time: 9:50 10:00 10:10 10:20 <br /> Final Reading(RF): 5 Psi 5 Psi 5 Psi 5 Psi <br /> Test Duration: 1 Hour 1 Hour 1 Hour 1 Hour <br /> Change in Reading(RF-Rr): 0 Psi 0 Psi 0 Psi 0 Psi <br /> Pass/Fail Threshold or No Loss in Psi No Loss in Psi No Loss in Psi No Loss in Psi <br /> Criteria: <br /> Test Result: Pass Pass Pass Pass <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />