My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2020 4:31:56 PM
Creation date
3/25/2020 11:38:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W RCB, January 2002 Page t of <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: Piping Manufacturer ❑ Industry Standard ❑ Professional Engineer <br /> Other(Spec) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: ,e a to-. C - 5 l+Voe 10 Equipment Resolution: l /D 19 szt- <br /> Piping Run# Piping Run# Piping Run # '7 aping Run# <br /> Piping Material: i 64,Ki (4, 5 5 F5S <br /> Piping Manufacturer: , � d <br /> Piping Diameter: I e �, ► 1 •� <br /> Length of Piping Run: Ap 0 yvX. 101) 0 00x ' ? ddx- too p <br /> Product Stored: I I I I <br /> — ItA u(a tv- t-,4. <br /> Method and location of C l w�St,t I c(Q- 5ket I T--s+ C lo-,- 6lAw"t-le,1 - <br /> piping-run isolation: 6,444 tlw <br /> Wait time between applying <br /> pt sure vacuum/water and <br /> test: So I vt crt 5 ;e to r--r ,l l c.r * -e5 -36 <br /> Test Start Time: U , ,fid /D ; g v <br /> Initial Reading(111): S YDS 7r. 5 S 10 5-�:r <br /> Test End Time: /1 , 3d <br /> Final Reading(RF): S P 5 -T" <br /> Test Duration: , k p k ✓- <br /> Change in Reading(RF-R,): <br /> Pass/Fail Threshold or <br /> Criteria: NO Lo •1 f 5 T .1 'i✓A P5-17 I A)6 L050,-1- P 5Y -Z <br /> Test Result: Pass ❑ Fail YPass ❑ Fail Pass ❑Fail ❑ Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.