My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2020 4:31:56 PM
Creation date
3/25/2020 11:38:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI _ <br /> ■ :�f5Eu1.1 7::.; .. ��r:il <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within&e State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23, California Co <br /> Regulations Iripf 0 S 2010 <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be preparAAW JOA:11"i_;!J COUNTY <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system ✓IITARO'NWENTAL <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of tesq-W LTH DEPARTMENT <br /> A. General Information <br /> Facility <br /> N,,,,o. SKY MART VALERO Bldg.No.: _ <br /> Site <br /> Artdraca• 713 N ELDORADO ST City: STOCKTON CA Zip: <br /> Facility Contact <br /> Pr rcnn• ALI Contact Phone No.: (209)939-1755 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 4/28/2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/servi ed: _ <br /> Tank ID: 87 oct Tank ID 91 oct <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 302 ® Annular Space or Vault Sensor. Model: 302 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model. <br /> ® Electronic Line Leak Detector. Model: PLLD ® Electronic Line Leak Detector. Model. PLLD <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DSL Tank ID NA <br /> ® In-Tank Gauging Probe. Model: MAG 1 [I In-Tank Gauging Probe. Model. <br /> W <br /> ® Annular Space or Vault Sensor. Model: SPLIT 91 E] Annu r Space or Vault Sensor. Model. <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ® Fill Sump Sensor(s). Model: 208 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: PLLD ❑ Electronic Line Leak Detector. Model: <br /> i <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor, Mo el: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model I i Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Mo(el: 208 <br /> ® Shear Valve(s). ® Shea Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser <br /> ID: 5-6 Dispen erID: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shea Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispen er ID: 11-12 <br /> ® Disp nser Containment <br /> ® Dispenser Containment Sensor(s). Model 208 Sen or(s). Model: 208 <br /> ® Shear Valve(s). ® She r Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Disp nser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification Is information(e.g.manufacturers'checklists)necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable f generating such reports,I have also attached a <br /> copy of the report;(check all that applv): ®System set-up ®Alarm history report <br /> Technician Name(print): DAVE WINKLER Signature: �,,_V__) <br /> Certification No.: 5263373-UT License N : 08-1739 <br /> Testing Company Name: AFFORDA-TEST Phone No _ 209)744-0113 <br /> Testing Company Address: 416 2 STREET GALT,CA 95632 Date of Te sting/Servicing: 4-28-2010 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.