My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2003 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2023 11:14:59 AM
Creation date
3/25/2020 4:23:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2008
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page a of <br /> 7. UNDER-DISPENSER CONTAINMENT"Q TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard ofessional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: Pressure ❑Vacuum 'Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Equipment Resolution: <br /> UDC#q Ito UDC# / 1/Z jUDC# IUDC# <br /> UDC Manufacturer: ( eo11cv2,.cr~ V_4101 <br /> UDC Material: Ft r. ,; jC <br /> UDC Depth: "' if <br /> Height from UDC Bottom to Top 4 <br /> of Highest Piping Penetration: 1 I ala <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: Do <br /> Portion of UDC Tested J4+er L. utr-4+�t y !lou, <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both Yes ❑No ❑NA es ❑No ❑NA ❑Y No ❑NA ❑Y ❑No ❑NA <br /> product and water)?" <br /> Turbine shutdown response time -7 W . s4t . <br /> Is system programmed for fail- yes ❑No ❑NA Yes ❑No ❑NA ❑Yes No ❑NA El V NJ ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be <br /> operational?* es ❑No ❑NA es ❑No ❑NA ❑Yes NNo ❑NA ❑Yes ❑NA <br /> Wait time between g <br /> pressure/vacu water d <br /> starting test ,*rrrrw�r s /D llea.0 L -S <br /> Test Start Time: 9:S 17:10 <br /> Initial Reading(RO: l ��.-c ✓i4� �_"(00 <br /> Test End Time: <br /> Final Reading F): <br /> Test Duration: 31.0 pw 4--S 30/yt"4f �s <br /> Change in Reading RF-RI): fs 6 G a n lam~ <br /> Pass/Fail Threshold or Criteria: .005 30 ?oma ' <br /> Test Result: A Pass 0 Fail Pass ❑Fail, jh Pass ❑Fail ofipaig D Fa <br /> Was sensor removed for testing? es ❑No ❑NA ❑No ❑NA Yes ❑No ❑N ❑ es ❑No ❑N <br /> Was sensor properly replaced and ^es ❑No ❑NAeYes ❑No NA ❑Yes ❑No ❑NA k <br /> es ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to gny of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.