My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2003 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2023 11:14:59 AM
Creation date
3/25/2020 4:23:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2008
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11/24/2008 14: 06 2094654988 HMC PAGE 02/04 <br /> 1Vfonitoriti h System Certification. <br /> 4 <br /> D_ Rest lts of Testing/Servicing <br /> Soltwarc`,'crsion Installed: 27.04 <br /> Colin let the folio ing checklist: <br /> NYes 171 No* is the audible alanr operational? <br /> ® Yes ❑ No* is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected,functionally tested, and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a. remote monitoring station, is all communications equipment (e.g_, modem) <br /> ® N/A operational? <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all ihofapply) N Sump/Trench Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/& .onnection? 1Z Yes; ElNo. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> ,13 N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? if so,at what percent of tank capacity does the alarm trigger? % <br /> El Yes* ® No Was any monitoring equipment replaced? Ifycs, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section F,,, below. <br /> N Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all khat apply) <br /> ❑ Product; ❑ Water, If yes, describe causes in Section 1;,below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable <br /> ® Yes ❑ No* j Is all monitoring equipment operational per manufacturer's specifications? <br /> * 1n Sectinn E below,describe how and when these deficiencies were or will be corrected. <br /> E_ Comrients: Vent Box sensor 208, Small amount of water in sumps pumped out. Alarm history given to iNSP. <br /> Page 2 of � <br />
The URL can be used to link to this page
Your browser does not support the video tag.