My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2003 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2023 11:14:59 AM
Creation date
3/25/2020 4:23:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2008
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method By: Manufacturer • Industry Standard Professional Engr. Other(see below) <br /> Test Method Uses: Pressure vacuum • Hydrostatic Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Description Disp#9/10 Disp# 11/12 <br /> UDC manufacturer Total Containment Total Containment_ <br /> UDC material FRP FRP <br /> UDC depth (inches) 28" 28" <br /> Height from UDC bottom to highest 10" 10" <br /> piping penetration <br /> Height from UDC bottom to lowest 4" 4" <br /> electrical penetration <br /> T pe of shut-down present Sensor Sensor <br /> Condition of UDC prior to testing Dry Dry <br /> Portion of UDC tested Entire Entire <br /> Was sensor removed for testing? Yes Yes <br /> Was sensor properly replaced after testing? Yes Yes <br /> Wait time for water level to stabilize (hr:min) 0:10 0:10 <br /> Depth of water level from UDC bottom (in.) 12" 12" <br /> Test start time 9:28 AM 9:28 AM <br /> Test end time 9:43 AM 9:43 AM <br /> Test duration (hr:min) 0:15 0:15 <br /> Change in water level l 0.000 inches) 0.001 0.002 <br /> Pass/Fail threshold (0.005 inches/'/2 Hr.) 0.005 0.005 <br /> TEST RESULT PASS PASS <br /> Comments: <br /> C 2003 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.