My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
0
>
2900 - Site Mitigation Program
>
PR0009171
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2020 11:50:21 AM
Creation date
3/30/2020 11:19:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0009171
PE
2960
FACILITY_ID
FA0004011
FACILITY_NAME
PORT OF STOCKTON-FUEL TERMINAL
STREET_NUMBER
0
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95203
CURRENT_STATUS
01
SITE_LOCATION
NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
577
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Re0onal Water Quality Control Board <br /> Central Valley Region <br /> Robert Schneider, Chair <br /> Winston H.Hickox Gray Davis <br /> Secretnryfor Sacramento Main Office Governor <br /> Environmental Intemet Address: http://www.swicb.ca.gov/i,wgcb5 <br /> Protection 3443 Routier Road,Suite A,Sacramento,California 95827-3003 <br /> Phone(916)255-3000 FAX(916)255-3015 <br /> 18 April 2001 <br /> Mr. Robert Donovan <br /> Tesoro Petroleum Companies <br /> 3450 344th Way, Suite 100 <br /> Auburn, WA 98001-5931 <br /> `J <br /> REVIEW OF THE WORK PLAN FOR WELL INSTALLATION AND RESPONSE TO <br /> COMMENTS, STOCKTON TERMINALS TECHNICAL COMMITTEE, PORT OF <br /> STOCKTON FUEL TERMINALS, SAN JOAQUIN COUNTY <br /> We have reviewed the 9 April 2001 Workplan for Well Installation (Work Plan) and the 9 April 2001 <br /> Response to Review of the Groundi-vater Investigation Report (Letter) submitted by IT Corporation (IT) <br /> on behalf of the Stockton Terminals Technical Committee (STTC) in Stockton. The STTC is composed <br /> of ARCO Products, ST Services, Tesoro Petroleum Company, and Time Oil. The Work Plan discusses <br /> the proposed field activities to install 17 groundwater monitoring wells throughout the four water- <br /> bearing zones (A, B, C, and D) at the site. The Letter responds to the Board staff comment letter dated <br /> 12 March 2001 on the 23 January 2001 Groundwater Investigation Report. <br /> We have the following comments on the Work Plan and Letter: <br /> 1. The last sentence of section Task 1 —Prefield Activities of the Work Plan is not complete. STTC <br /> should provide all pertinent information on pre-field activity contacts. <br /> 2. The proposed slot size for the monitoring well screen should be included in the text, not just the <br /> appendix. <br /> 3. The Work Plan does not propose groundwater sampling of the newly installed groundwater <br /> monitoring wells. These wells should be sampled 24 to 48 hours after development and samples <br /> analyzed pursuant to Monitoring and Reporting Program 5-01-819. <br /> 4. During groundwater monitoring well development, turbidity and temperature must be included in <br /> the water quality parameters. <br /> 5. Equipment blank samples should be collected to monitor for potential cross-contamination and <br /> ensure proper decontamination procedures were followed. <br /> California Environmental Protection Agency <br /> Co Recycled Paper <br /> The energy challenge facing California is real. Every Californian needs to take immediate action to reduce energy consumption. <br /> For a list of simple ways you can reduce demand and cut your energy costs,see our Web-site at http://www.swrcb.ca.gov/mgcb5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.